期刊文献+

输电钢管塔空间KK型管板连接节点极限承载力 被引量:2

Ultimate strength analysis of KK-type tube-gusset plate connections in transmission steel tubular tower
下载PDF
导出
摘要 空间KK型管板连接节点作为输电钢管塔中最主要的节点型式,其安全性是整个塔架结构安全的重要保证。相比较于平面K型节点,在考虑实际结构中节点空间效应后的KK型节点的受力性能更为复杂。在平面K型管板节点的试验研究基础上,对两类空间KK型管板节点展开参数化分析,重点讨论了节点几何尺寸参数和主管轴压应力比等因素对节点极限承载力的影响变化规律。结合大量有限元参数分析所得计算结果,并综合考虑各种因素对节点极限承载力的影响,提出了空间KK型管板连接节点在主管管壁局部屈曲破坏模式下的极限承载力建议计算方法。 Multiplanar KK-type tube-gusset plate connections are the main joint types in transmission steel tubular tower,the safety of the joints are critical to the entire tower.Compared to K-joints,the mechanic characteristics of KK-joints are more complex after considering the multiplanar effects in the actual structure.Based on the bearing capacity test of K-type tube-gusset plate connections,parameterization analysis on the two kinds KK-type tube-gusset plate connections are conducted respectively,the geometric parameters and the axial force of the main tube together with other factors on the influence of the ultimate bearing capacity of multiplanar KK-joints are studied in detail.According to the results of large scale finite element parametric analysis,and considering the influence of various factors on the ultimate strength of the joints,calculation formulas of KK-type tube-gusset plate connections ultimate bearing capacity are proposed.
出处 《土木建筑与环境工程》 CSCD 北大核心 2016年第6期71-81,共11页 Journal of Civil,Architectural & Environment Engineering
基金 重庆市科技项目基础与前沿研究计划(CSTC2C2015JCYJA00041)~~
关键词 输电钢管塔 空间KK型 管板连接节点 极限承载力 transmission steel tubular tower KK-type tube-gusset plate connections ultimate strength
  • 相关文献

参考文献4

二级参考文献26

  • 1陈誉,彭兴黔,赵宪忠.钢管搭接节点的研究现状[J].基建优化,2007,28(5):154-157. 被引量:1
  • 2余世策,孙炳楠,叶尹,应建国.高耸钢管塔结点极限承载力的试验研究与理论分析[J].工程力学,2004,21(3):155-161. 被引量:40
  • 3赵宪忠,闫澍,陈龙中,陈以一,童乐为,范重.国家体育场桁架柱外柱节点试验研究[J].建筑结构学报,2007,28(2):81-86. 被引量:12
  • 4送电用钢管铁塔制作基准[s].东京:日本铁塔协会,1985.
  • 5Woo-Bum Kim.Ultimate strength of tube-gusset plate connections considering eccentricity[J].Engineering Structures,2001(23):1418-1426.
  • 6日本铁塔协会.输电线路钢管塔制作基准[S].东京:丸善株式会社,1985.
  • 7Architectural Institute of Japan.Recommendations for the design and fabrication of tubular structures in steel[S].Tokyo:Japanese Steel Construct,1990.
  • 8Saeko S.Experimental study on strength of tubular steel structures[J].Japanese Steel Construct,1974,10(102):37-68.
  • 9KEPCO.Specification for electric transmission tower design[S].Tokyo:Japanese Society Steel Construct,1991.
  • 10Packer J A,Henderson J E.Design guide for hollow structural section connections[M].Markham:Canadian Institution Steel Construct,1992:88-124.

共引文献26

同被引文献11

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部