摘要 目的评价第二代双源CT行Flash大螺距扫描模式应用小剂量对比剂团注测试(test bolus)在肺动脉成像中的应用价值。方法选取医院2014年5月至2015年6月收治的怀疑肺动脉栓塞行CT肺动脉成像(CTPA)检查的患者80例,依据随机数字表法分成A,B两组,A组用大螺距(3.0)扫描应用test bolus技术;B组常规扫描应用对比剂团注跟踪技术(bolus track),比较两组的图像质量和辐射剂量。结果 80例肺动脉成像均能满足诊断要求,但A组肺动脉图像显示明显好于B组,并且辐射剂量小。结论在CTPA中使用大螺距扫描及test bolus技术比用常规扫描及bolus track技术在低辐射条件下能获得更好的肺动脉成像质量。
出处 《医疗装备》 2016年第23期62-63,共2页 Medical Equipment
  • 相关文献

参考文献5

二级参考文献37

  • 1Siegel MJ, Ramirez (;.iraldo JC, Hildebolt C, et al. Automated low- kilovohage selection in pediatric computed tom ography angiogra- t)hy:phantom study evaluating effects on radiation dose and image quality[J]. Invest Radiol,2013,48(8):584-589.
  • 2Duan X, McCollough C. Risks. benefits and risk reduclion strate- gies in thoracic CT imaging[J]. Semin Respir Crit Care Med, 2(114.35(1) :83-90.
  • 3Ramadan SU, Kosar P, Sonmez I, et aI. Optimisation of contrast medium volume and injection-related factors in CT pulmonary an- giography:64-slice CT study[J]. Eur Radiology, 2010, 20 (9): 2100-2107.
  • 4Roggenland D, Peters SA, Lemburg SP, et al. CT angiography in suspected pulmonary embolism: impact o{ patient characteristics and different venous lines on vessel enhancement and image quali- ty[J]. AJR,2008,190(6) :W351-W359.
  • 5Patel S, Kazeroomi EA, Cascade PN. Pulmonary embolism: optimi- zation of small pulmonary artery visualization at multi-detector row CT[J]. Radiology, 2003,227 (2) : 455-460.
  • 6Wang Z, Chen Y, Wang Y, et al. Feasibility of low-dose contrast medium high pitch CT angiography for the combined evaluation of coronary, head and neck arteries [J]. PLoS One, 2014, 9 ( 3 ) e90268.
  • 7Helck A, Bamberg F, Sommer WH, et al. Optimized contrast vol ume for dynamic CT angiography in renal transplant patients u sing a muhiphase CT protocol[J]. Eur J Radiol,2011,80(3) :692-698.
  • 8Siegel M J, H ildeboh C,Bradley D. Effects of automated kilovolt age selection technology on contrast-enhanced pediatric CT and CT angiography[J]. Radiology, 2013,268 (2) : 538-547.
  • 9Lee SW,Kim Y,Shlm SS,et al. Image quality assessment of ultra low-dose chest CT using sinogram affirmed iterative reconstruc- tion[J]. Ear Radiol,2014,24(4):817-826.
  • 10Mayo J, Thakur Y. Pulmonary CT angiography as first- line imaging for PE: image quality and radiation dose considerations. Am J Roentgenol, 2013, 200(3): 522-528.