摘要 在再热蒸汽烟温挡板改造基础上对挡板控制程序进行优化,解决了运行过程中烟气挡板轴承因环境温度高、灰尘大频繁卡涩这一难题,减少了烟温挡板的非线性对再热汽温控制精度的影响、再热汽温调节品质达到优良,对机组安全、稳定、经济运行具有重要意义。 Smoke in the reheat steam temperature flap reconstruction based on optimize the damper control program, to solve the running process of flue gas damper bearing due to environment temperature is high, the problem of frequent jamming at dust big, reduce the smoke temperature baffle of the nonlinear effect of reheat steam temperature control precision, reheat steam temperature regulation, to fine quality on safety, stable and economic operation of units is of great significance.
出处 《机电工程技术》 2016年第11期123-126,共4页 Mechanical & Electrical Engineering Technology
关键词 再热汽温 轴承卡涩 逻辑优化 模糊控制 分组控制 reheat steam temperature bearing unsmooth logic optimization fuzzy control group control
  • 相关文献

参考文献4

二级参考文献16

  • 1史习仁.火力发电设备技术手册[M].,2000..
  • 2郑大钟.线性系统理论[M].北京:清华大学出版社,2000..
  • 3Harry L Trentelman, Anton A Stoorvogel, Malo Hautus. Control theory forlinearsystems[M]. Berlin: Springer, 2001.
  • 4Julian Stoev, Jin Young Choi, Jay Farrell. Adaptive control for output feedback nonlinear systems in the presence of modeling errors[J].Automatica, 2002, 38, 1761-1767.
  • 5Jong-Koo Park, Dong-Ryeol Shin, Tai M. Chung. Dynamic observers for linear time-invariant systems[J]. Automatica, 2002, 38, 1083-1087.
  • 6Kay-Soon Low, Hualiang Zhuang. Robust model predictive control and observer for direct drive applocation[J]. IEEE Trans. Power Electronics. 2000, 15(6): 1018-1028.
  • 7Eduardo Gallestey, Alec Stothert, Marc Antoine etal. Model predictive control and the optimization of power plant load while considering lifetime consumption[J]. IEEE Trans. Power Systems. 2002, 17(2):186-191.
  • 8Katsuhiko Ogata. Modern control engineering (Second Edition) [M].Prentice-Hall, Englewood Cliffs, New Jersey, 1990.
  • 9刘鸿国.超超临界机组锅炉的优化状态检修及管理[J].华电技术,2009,31(9):34-36. 被引量:2
  • 10常海龙.超超临界燃煤机组循环水系统优化分析[J].华电技术,2010,32(4):16-17. 被引量:1