摘要
京能宁东发电有限责任公司2号机组汽轮机高调阀由于调阀重叠度曲线拟合性不好,机组负荷在580 MW时GV4调阀存在大幅波动情况。通过高调阀阀门在线试验,优化重叠度曲线,很好地解决了这一问题。试验结果表明优化后的重叠度曲线能保证阀门的流量特性,并能提高汽轮机组的效率。
Due to the fitting of overlap degree curve is not well, when 580 MW load GV4 governing valve has large range fluctuation problem at steam turbine of No.2 generators in Ningxia Jingneng Ningdong Power Generation Llimited Company, Through on-line test for governing valve and optimizing overlap degree curve, solves this problem. The test result shows that the valve covers between GV1 and GV2 exists gap. Optimized overlap degree curve can guarantee the flux characteristic of the valves, and improve the efficiency of steam turbine. The overlap degree optimization test can provide reference for overlap degree curve optimization of governing valve of the same type generators.
作者
谢晔
XIE Ye(Ningxia Jingneng Ningdong Power Generation Co., Ltd., Yinchuan Ningxia 750400, Chin)
出处
《宁夏电力》
2016年第5期66-70,共5页
Ningxia Electric Power
关键词
汽轮机
高调阀
重叠度
steam turbine
governing valve
overlap degree