摘要
对某自备电厂330MW机组锅炉进行了节能诊断试验。通过对锅炉效率、空预器漏风、辅机耗电率等进行现场测试,分析了影响机组运行经济性的主要能耗损失及其产生的原因,并从运行调整着手提出该机组锅炉系统的节能降耗措施。
The energy-saving diagnostic test is taken for a self-provided power plant 330 MW unit boiler. The running efficiency is analyzed through the test for boiler efficiency, air leakage, and auxiliary power consumption rate. The main cause of energy losses is found, and the operation adjustment is put forward.
作者
刘志华
武岳
郭松涛
Liu Zhihua Wu Yue Guo Songtao(China Datang Northwest Electric power test and Research Institute Xi'an 710065)
出处
《中国特种设备安全》
2016年第11期52-55,共4页
China Special Equipment Safety
关键词
330MW
锅炉
能耗诊断
节能分析
330MW
Boiler
Energy diagnosis
Energy-saving
potential