摘要
本文从改造方案设计、变频器配置、改造实施过程以及变频器在火电厂一次风机、二次风机的成功应用,论述了四川白马循环流化床示范电站有限责任公司一次风机、二次风机实施变频改造的技术过程。变频改造后,系统运行稳定、安全可靠、节能效果显著。
This article discusses the technology process of the variable frequency modification for the first fan and the second fan of 600 MW thermal power unit in Neijiang Baima thermal power plant through the design,configuration and the modification process.After the VFD installation,the first fan and the second fan system is running stably,safely and reliably and energy-saving effect is remarkable.
出处
《变频器世界》
2016年第11期82-86,97,共6页
The World of Inverters
关键词
一次风机
二次风机
高压大功率变频器
节能改造
First Fan
Second Fan
High-voltage High-power Variable Frequency Drive
Energy-saving