电力信息交换总线高效、完整、可靠的数据传输是输、变、配、用信息交互关键。文章从适配器、总线运行、消息传输与数据转换各环节综合考虑和分析,应用多进程、多隔离负载均衡、动态路由机制、基于缓存技术的数据重传等技术,提出电力信息交换总线数据传输整体可靠性机制和策略。通过大量现场运行应用表明该可靠性技术可有效提升电力信息交换总线数据传输效率,数据传输安全、稳定、可靠。
The efficient, complete and reliable data transmission of electric power information exchange bus is the key along application system information interaction. This article analyses the adapter, bus operation, information transmission and data conversion. The multi-process technology, load balancing about multi-isolation, dynamic routing mechanism, data retransmission technology based on caching is used to ensure data transmission reliability of power information exchange bus. Experimental results validate that the integrated reliability scheme can improve the efficiency of data transmission, ensuring the stablity and reliablity of data transmission.
出处
《供用电》
2016年第12期58-63,共6页
Distribution & Utilization
关键词
电力信息交换总线
分布式一致性
动态路由
缓存数据重传
可靠性技术
power information exchange bus
distributed consistency
dynamic routing
cache data retransmission
reliabilitytechnology