期刊文献+

进气喷嘴对气水脉冲管道冲洗效果影响的数值模拟 被引量:1

Numerical Simulation of Impact of Air-Inlet Nozzle on Effect of Air-Water Pulse Pipeline Flushing
下载PDF
导出
摘要 应用气水脉冲管道冲洗法冲洗管道时,进气喷嘴尺寸和安装位置对冲洗效果有很大的影响。作者采用CFD方法,对进气喷嘴尺寸和安装位置不同的管道两相流进行数值模拟,得到管道内水流对管道上/下壁面剪切力变化曲线。综合模拟结果得出,进气喷嘴尺寸为0.25 D、设置在管道中间时,能得到较好的冲洗效果。 Air-inlet nozzle size and installation location have a great influence on the flushing effect when cleaning pipeline uses air-water pulse pipeline flushing technology. CFD method is used to numerically simulate the two-phase flow for pipeline with different air-inlet nozzle sizes and installation locations by the authors and a curve of upper-walL/lower-wall shear stress is obtained. Comprehensive simulation results conclude that washing effect will be better while the air-inlet nozzle size is 0.25 D, setting in the middle of the pipeline.
出处 《净水技术》 CAS 2016年第6期96-99,共4页 Water Purification Technology
基金 十二五国家水体污染控制与治理重大专项(2012ZX07403-002) 上海市科委科研项目(15XD1521000) 哈尔滨工业大学城市水资源与水环境国家重点实验室开放基金项目(QA201613)
关键词 气水脉冲管道冲洗 进气喷嘴 计算流体力学(CFD) 数值模拟 壁面剪切力 air-water pulse pipeline flushing air-inlet nozzle computational fluid dynamics (CFD) numerical simulation wall shear stress
  • 相关文献

参考文献4

二级参考文献44

  • 1陆丽,邓保庆,李勋栋,王静.不同臭氧接触池性能的CFD模拟[J].水资源与水工程学报,2012,23(3):81-83. 被引量:5
  • 2刘文君,崔磊.应用计算流体力学优化清水池水力效率[J].中国给水排水,2005,21(5):1-5. 被引量:10
  • 3Hudson J A. The impact of sediment on open channel flow measurement in selected UK experimental basins. Flow Measurement and Instrumentation, 2004,15:49-58.
  • 4Wu W M,Rodi W,Wenka T. 3D numerical modeling of flow and sediment transport in open channels. Journal of Hydraulic Engeering, 2000,1 : 4 - 15.
  • 5王福军.计算流体力学分析-CFD软件原理与运用.北京:清华大学出版社,2004.
  • 6Rameshwaran P, Naden P S. Three - Dimensional numerical simulation of compound channel flows. Journal of Hydraulic Engineering, 2003,645-652.
  • 7Orlandi P,Leonardi S, Tuzi R, et al. Direct numerical nimulation of turbulent channel flow with wall velocity disturbances. Physics of Fluids, 2003,15(12),3587-3601.
  • 8Butterfield P W, Camper A K, Biederman J A, et al. Minimizing biofilm in the presence of iron oxides and humic substances.Water Research, 2002, 36(15) : 3898-3910.
  • 9Emming H C, Wingender J. Relevance of Microbial Excellular Polymeric Substances (EPSs) part I: Structural and Ecological Aspects. Water Science Technology, 2001, 43(6): 1-8.
  • 10Edwards M. Controlling corrosion in drinking water distribution systems: a grand challenge for the 21st century. Water Science and Technology,2004, 49(2) : 1-8.

共引文献30

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部