期刊文献+

防振条对蒸汽发生器传热管完整性的影响分析 被引量:10

Effect of Anti-Vibration Bar on Steam Generator Tube Integrity
原文传递
导出
摘要 以二代加压水堆核电厂蒸汽发生器(SG)为例,分析了防振条组件对SG传热管完整性可能产生的影响。分析表明:发现防振条自身扭转、防振条与传热管之间的间隙、防振条的下插深度等对传热管的完整性影响较大。为提高传热管在役运行的可靠性,防振条的设计中对防振条组件(AVB)与SG传热管之间的设计间隙应作充分的考虑,避免在装配时对管束和AVB施加异常外力并确保同组AVB的下插深度一致。 The anti-vibration bars are critical to the integrity of tubes for steam generator during operation. Taking the steam generator of Generation 2+ for example, the potential effects of anti-vibration bars on the integrity of SG tube is analyzed. It is concluded that the anti-vibration bar twist, the gap between anti-bibration bar and tube, and the insertion depth of the anti-vibration bar are very important to the tube integrity. Based on the conclusions, optimizations are proposed to make the tubes more reliable during operation.
出处 《核动力工程》 EI CAS CSCD 北大核心 2016年第6期109-112,共4页 Nuclear Power Engineering
关键词 防振条 扭转 间隙 下插深度 Anti-vibration bar(AVB), Twist, Gap, Insertion depth