摘要
目的:回顾分析山西省中医院ABO血型测定结果,总结造成ABO血型正反定型不符的原因,并提出解决方法。方法:采用微柱凝胶法和试管法对住院及门诊患者进行ABO血型正反定型测定。结果:2014年1月-2016年1月住院及门诊患者7 850例,其中ABO血型正反定型不符20例(0.25%)。其中冷凝集9例,亚型2例,自身凝集1例,抗体减弱4例,先天性无ABO抗体1例,因输血或妊娠发生不规则抗体2例,近期输过异型红细胞1例。结论:对ABO血型正反定型不符,山西省中医院现有技术手段无法定型的ABO血型样本,可以采用基因检测法等其他检测手段正确鉴定ABO血型,从而保证临床输血的安全性。
Objective:To review and analyze the test results of ABO blood group in hospital,summarize the reasons for the discrepancy of the forward and reverse ABO typing,and put forward to the solution. Methods:Microtubes gel method will be ap-plied to test the forward and reverse type of the ABO blood group for patients. Results:All 7 850 patients were examined for the forward and reverse typing of ABO blood group. The discrepancies happened in 20 cases of the forward and reverse ABO group type,which takes 0. 25% of the total number of detection. There were 9 cases of cold agglutination,2 cases of subtype,1 case of self - agglutination,4 cases of antibody weakening,1 case of congenitally non ABO antibody,and 2 cases of irregular anti-body due to blood transfusion or pregnancy,1 case of transfused with different blood type recently. Conclusion:For those ABO blood group cases with forward and reverse discrepancies,which couldn't be stereotyped by the existing technology in our hos-pital,we can adopt the gene detection method and other testing means to identify the ABO blood group correctly,so as to ensure the safety of the clinical blood transfusion.
出处
《临床医药实践》
2016年第12期922-923,共2页
Proceeding of Clinical Medicine
关键词
ABO血型系统
正反定型
血型鉴定
ABO blood - group system
discrepancy of the forward and reverse
blood grouping