期刊文献+

七格污水处理厂提标改造工程设计 被引量:10

Design of Upgrading and Reconstruction Project of Qige Wastewater Treatment Plant
原文传递
导出
摘要 介绍了七格污水处理厂一、二、三期提标改造工程改造前后的处理工艺、设计参数和运行状况,提标改造工程均采用深床滤池工艺,并对原生物反应池、污泥回流系统、除臭系统等进行了技术改造。改造后出水水质可稳定达到《城镇污水处理厂污染物排放标准》(GB 18918—2002)一级A标准,可为同类污水处理厂升级改造提供参考。 The treatment processes, design parameters and operating status in Qige WWTP first-,second- and third-phase projects before and after the upgrading and reconstruction were introduced. Deepbed filter technology was used for upgrading and reconstruction, and the original biological reaction tank,sludge return system and deodorization system were technically reconstructed. After the reconstruction,the effluent quality could meet the first level A criteria specified in the Discharge Standard of Pollutantsfor Municipal Wastewater Treatment Plant (GB 18918 -2002). The project can provide reference for theupgradingand reconstruction of similar sewage treatment plants.
出处 《中国给水排水》 CAS CSCD 北大核心 2016年第24期118-121,共4页 China Water & Wastewater
关键词 污水处理厂 提标改造 深床滤池 碳源 WWTP upgrading and reconstruction deep bed filter carbon source
  • 相关文献

参考文献2

二级参考文献12

  • 1GBJ16-87.建筑设计防火规范.[S].,..
  • 2GB50058-92.爆炸和火灾危险环境电力装置设计规范.[S].,..
  • 3GB50160-92.石油化工企业设计防火规范.[S].,..
  • 4刘建伟,刘俊新,李琳.复合式生物除臭反应器处理城市污水处理厂恶臭气体[J].环境工程学报,2007,1(7):78-82. 被引量:20
  • 5中国化工市场信息,2000,16.
  • 6孙方震,侯耀先译.容器外可燃蒸气云爆炸.北京:化学工业出版社,1986
  • 7石油化学工业部化工设计院等.氮肥工业设计手册理化数据分册.北京:石油化学工业出版社,1997
  • 8National Fire Protection Association. Flammable and Combustible Liq uids Code, ANSI/NFPA30,
  • 9危险货物品名录GB12268-90
  • 10刘芳.H_2S废气处理研究进展[J].环境科技,2009,22(1):71-74. 被引量:7

共引文献22

同被引文献66

引证文献10

二级引证文献68

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部