摘要 传统电力系统可靠性评估均基于各自电压等级单独计算,虽能够发现各级电网的薄弱点,但不能体现上下级电网间的相互影响。本文考虑了主网影响和不同变电站主接线模式,建立了一种自上而下的全电压等级的可靠性评估方法,从而实现考虑上级电网影响的配电网可靠性评估,并以实际电网为算例,分别计算传统可靠性评估和全电压等级可靠性评估的系统可靠性指标。计算结果表明,本文提出的全电压等级的可靠性评估方法所计算的指标更能真实反映用户实际供电可靠性水平。最后,通过对比不同变电站接线模式下用户可靠性指标,分析了接线优化对用户可靠性的影响。 Traditional reliability assessment methods of pow-er system are based on their respective voltage grade,the weak spot of their own system can be discovered in this way, but it can’t reflect the interaction between transmission sys-tem and distribution system.Considering the effect of trans-mission system and substation main electrical wiring,a top-down approach about overall voltage level reliability assess-ment is proposed in this paper.Taking an actual grid as ex-ample,the result shows that reliability index which is calcu-lated by proposed method can truly reflect the power supply reliability level.Through the comparison of users’reliability index,the influence of different substation main electrical wiring is analyzed.
作者 许鹏程 陈启 刘宗歧 金秋龙 刘文霞 曹斌 王舒 XU Pengcheng CHEN Qi LIU Zongqi JIN Qiulong LIU Wenxia CAO Bin WANG Shu(State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source (North China Electric Power University), Beijing 102206, China Ningbo Electric Power Bureau, Ningbo 315012, China Sichuan Electric Power Design & Consulting Co. , LTD. , Chengdu 610016, China)
出处 《现代电力》 北大核心 2016年第6期46-50,共5页 Modern Electric Power
关键词 全电压等级 配电网 主网 主接线 可靠性评估 overall voltage level distribution network transmission system substation main electrical wiring relia-bility assessment
  • 相关文献

参考文献4

二级参考文献60

共引文献73

同被引文献87

引证文献8

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部