摘要
针对传统模极大检测算法暂态电能质量扰动持续时间短、随机性以及过零点难以检测等问题,提出基于动态窗的改进小波模极大值暂态信号扰动检测方法。对过零点时刻的扰动,在动态窗检测的基础上,通过系数变换,改善过零点时刻检测不明显的问题。运用Matlab软件进行的计算机仿真结果表明,该方法能准确地对暂态电能质量扰动进行检测与定位,精度较高且易于实现。
Because short duration,randomness and zero point are hard to detect for transient power quality disturbance,a transient signal disturbance detection method based on dynamic window of improved wavelet modulus maxima is presented. For passing zero point disturbance,on the basis of dynamic detection window,through the coefficient of transformation, improve the unconspicuous problem of the passing zero point.Simulation results show that the method can accurately detect and locate the transient power quality disturbances,precision is high and easy to implement.
出处
《吉林大学学报(信息科学版)》
CAS
2016年第6期761-766,共6页
Journal of Jilin University(Information Science Edition)
基金
黑龙江省自然科学基金资助项目(E201410)
关键词
电能质量
扰动检测
模极大值
动态窗
power quality
disturbance detection
modulus maxima
dynamic window