摘要
从施工技术、自然环境、管口堵塞等方面,分析了建筑给排水管道出现渗漏现象的主要原因,并阐述了穿越楼板处、穿出外墙处与卫生间三者排水管道的施工技术要点,旨在保证给排水系统的正常运行。
From the construction technology, natural environment, tube blockage and other aspects, this paper analyzed the main reasons of leak-age phenomenon of building water supply and drainage pipeline, and elaborated the construction technology main points of across the floor, out of outer wall and toilet three drainage pipelines, to ensure the normal operation of water supply and drainage system.
出处
《山西建筑》
2016年第34期113-114,共2页
Shanxi Architecture
关键词
给排水管道
渗漏现象
防水处理
卫生间
water supply and drainage pipeline, leakage phenomenon, waterproof treatment, toilet