摘要
射频同轴电缆发热时间常数是指电缆加热到稳态温升的63.23%所需要的时间,是射频同轴电缆额定功率测试过程中的关键参数。基于发热时间常数的重要性,介绍了确定发热时间常数的方法,并指出了其在电缆超功率运行等方面的应用。
Radio frequency(RF)coaxial cable heating time constant means the time that the cable needs to be heated up to 63.23% of the equilibrium temperature rise and it is the key factor in the rated power test process of RF coaxial cable.Based on the significance of the heating time constant,the determination method of the constant is given.And the application of the cable in overpower operation is also introduced.
作者
殷海成
宣维刚
汤钧
张万经
YIN Haicheng XUAN Weigang TANG Jun ZHANG Wanjing(National Quality Supervision and Inspection Centre of Information Transmission Lines, Shanghai 201900, China)
出处
《光纤与电缆及其应用技术》
2016年第6期1-3,共3页
Optical Fiber & Electric Cable and Their Applications