摘要 [目的]建立简便、快速、高效的测定不锈钢容器中铅、镍、镉、铬、砷的方法。[方法]采用微量进样、冷凝雾化、在线添加内标物的方式对影响因素进行了研究,利用电感耦合等离子体质谱(ICP-MS)法直接测定不锈钢容器中铅、镍、镉、铬、砷。[结果]该方法线性范围宽,线性相关系数大于0.999,样品加标回收率83.8%~111.1%,相对标准偏差在10%之内。[结论]该方法具有快捷、准确、灵敏度高、精密度好等优点,可满足不锈钢容器中铅、镍、镉、铬、砷的检测要求。 [Objective] To establish a simple,rapid and efficient method to determine Pb,Ni,Cd,Cr,and As in stainless steelfood containers.[Method]With the aids of the micro-injection,condensation-atomization,method of adding internal standard online,influencing factors were studied,Pb,Ni,Cd,Cr,and As in stainless steel food containers were determined by ICP-MS.[Result] The established method had the broad linear-range characteristics,and the linear correlation coefficient was over 0. 999. Meanwhile,the adding standard recovery could up to 83. 8%-111. 1%,and the ralative standard deviation( RSD) was less than 10%. [Conclusion]The method is rapid,accurate,high sensitive and precision,which can meet the demand of Pb,Ni,Cd,Cr,and As detection in stainless steelfood containers.
作者 张家磊
出处 《安徽农业科学》 CAS 2016年第35期126-126,170,共2页 Journal of Anhui Agricultural Sciences
关键词 电感耦合等离子体质谱法 不锈钢制品 内标法 ICP-MS Stainless steel products Pb Ni Cd Cr As Internal standard method
  • 相关文献

参考文献4

二级参考文献24

  • 1谢华林,文海初.ICP-MS法测定陶瓷容器中重金属元素的研究[J].中国陶瓷工业,2004,11(3):32-33. 被引量:8
  • 2中华人民共和国卫生部.GB9684-1988.不绣钢食具容器卫生标准[S].
  • 3国家质量监督检验检疲总局.JJG 694-2009.原子吸收分光光度计[S].北京:中国计量出版社,2010.
  • 4GB5001-1985日用陶瓷分类[S].北京:中国标准出版社,1985.
  • 5中国轻工工艺品进出口商会.出口日用陶瓷质量安全手册[R].商务部对外贸易司,2009.
  • 6中国国家认证认可监督管理委员会.中华人民共和国国家认证认可监督管理局与美利坚合众国卫生和人类服务部食品药物管理局关于对美出口的调制、盛放或贮存食品和饮料的陶瓷器皿问题谅解备忘录[EB/OL].http://www.cnca.gov.cn/rjwgjhzb/sbhzjl/mzdyz/mg/6191.shtml.2006-10-18.
  • 7R. W. Sheets, S. L. Turpen, P. Hill. Effect of microwave heating on leac- hing of lead from old ceramic dinnerware [ J ]. The Science of the Total Environment, 1996 ( 182 ) : 187 - 191.
  • 8罗慧荣,李妙良.国外陶瓷工业标准[M].轻工业标准化编辑出版社委员会出版,1984:5-17.
  • 9Richard L. Lehman. Lead glazes for ceramic foodware[ R]. The Interna- tional Lead Management Center, 2002.
  • 10M.El Himri,A.Pastor,M.de la Guardia.Determination of uranium in tap water by ICP-MS.Anal Bioanal Chem,2003.367(2):151-156

共引文献14

同被引文献316

引证文献2

二级引证文献53

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部