期刊文献+

两种可吸收缝合线在鼻内镜手术中的应用 被引量:3

Application of two absorbable suture in endoscopic sinus surgery
下载PDF
导出
摘要 目的比较人工合成可吸收线与胶原蛋白可吸收线对鼻内镜手术切口愈合时间和拆线时疼痛情况。方法 100例鼻内镜手术随机分为A、B两组,每组50例。A组:采用胶原蛋白可吸收线;B组:采用人工合成可吸收线,比较两组切口愈合时间和拆线时疼痛情况。结果 A、B两组切口愈合无明显差异(P>0.05),但二组在脱略时间、拆线时疼痛有明显差异(P<0.05)。结论胶原蛋白可吸收线降解脱略时间与鼻内镜手术伤口愈合时间较匹配,是较为理想的选择。 OBJECTIVE To compare the application effect of synthetic absorbable suture and collagen absorbable suture in endoscopic sinus surgery. METHODS One hundred cases underwent nasal endoscopic surgery were randomly divided into A and B groups, and 50 cases in each group. A group used synthetic absorbable thread and B group used collagen absorption thread. The wound healing time and the pain during removing stitches were compared between two groups. RESULTS There was no significant difference in wound healing time between the two groups(P〉0.05), but there was significant difference in pain assessment(P〈0.05) between the two groups. CONCLUSION The collagen absorbable suture has well matched degradation time with wound healing and is an ideal choice in endoscopic sinus surgery.
出处 《中国耳鼻咽喉头颈外科》 CSCD 2016年第12期714-715,共2页 Chinese Archives of Otolaryngology-Head and Neck Surgery
关键词 内窥镜检查 缝线 人工合成可吸收线 胶原蛋白可吸收线 Endoscopy Sutures synthetic absorbable suture collagen absorbable suture
  • 相关文献

参考文献8

二级参考文献59

共引文献335

同被引文献37

引证文献3

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部