期刊文献+

电感耦合等离子体发射光谱法测定含锡矿石中的锡 被引量:7

DETERMINATION OF TIN IN TIN ORE CONTAINING BY INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROMETRY
下载PDF
导出
摘要 通过用过氧化钠分解试样,盐酸.酒石酸-双氧水浸取,电感耦合等离子体发射光谱法测定样品中的锡。该方法检出限为10μg/g,相对标准偏差为1.95%-4.83%。该方法经国家一级标准物质验证,分析结果与国家标准值相符,且实验步骤简单,快速准确,提高了工作效率,可用于大批量样品的检测。 In this paper, using sodium peroxide decomposition sample, - tartaric acid and hydrochloric acid leaching, hydrogen peroxide inductively coupled plasma emission spectrometry determination of tin in the sample. The method detection limit of 10μg/g, relative standard deviation is 1.95%-4.83%. Method is verified by national standard substances and the result of analysis is consistent with the values specified, and the experiment steps are simple, rapid accurate, improve the working efficiency, can be used for the determination of bulk samples.
作者 王艳超 刘金龙 Wang Yanchao Liu Jinlong(Geological Institute of China Chemical Geology and Mine Bureau, Zhuozhou, Hebei, 072754, Chin)
出处 《化工矿产地质》 CAS 2016年第4期242-245,共4页 Geology of Chemical Minerals
关键词 过氧化钠碱熔 电感耦合等离子体发射光谱法 快速准确 tin alkali fusion with Sodium peroxide Inductively Coupled Plasma-Atomic EmissionSpectrometry quickly and accurately
  • 相关文献

参考文献3

二级参考文献11

共引文献65

同被引文献82

引证文献7

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部