摘要
根据洪屏抽水蓄能电站设计参数的要求确定水泵水轮机设计比转速,采用CFD数值计算软件对水泵水轮机进行水力开发,并在福伊特海登海姆模型试验台进行了水力模型试验,通过两种试验结果对比分析,所开发的水泵水轮机各项水力性能能满足合同要求,并对水泵水轮机四象限特性曲线反"S"区特性进行了简单分析。
The specific speed was determined in accordance with the pump-turbine design parameters of Hongping pumped storage power station, the contest to results between CFD numerical simulation software for pump-turbine hydraulic research and Hydraulic model test was maded the UHD. The performance of the pump-turbine hydraulic development to meet the contract requirements, and according to the results have a simple feature analysis of the pump-turbine characteristic curve anti-quadrant "S" zone.
出处
《水电与抽水蓄能》
2016年第6期85-88,99,共5页
Hydropower and Pumped Storage