期刊文献+

一起110kV末端线路单相接地故障分析 被引量:3

Analysis of Single Phase Grounding Fault for 110k V Terminal Transmission Line
下载PDF
导出
摘要 随着科技的发展,各种生产设备和生活电器对供电电源的可靠性要求越来越高,电网运行方式和保护配合问题得到重视。本文结合一起110k V末端线路单相接地故障案例,运用Matlab仿真工具,深入分析了110k V电网末端线路单相接地故障现象,对末端站的保护配合提出建议。 With the development of science and technology, the requirements for reliability on various kinds of manufacturing equipments and living electric apparatus grows higher and higher, the operation mode and protection coordination of power grid has been paid more and more attention. Combining with an actual case, the article analyzed of a single phase grounding fault for 110 k V terminal transmission line with the Matlab, and put forward some suggestions on protection coordination of terminal transformer substation.
出处 《电气技术》 2016年第12期93-97,共5页 Electrical Engineering
关键词 零序电流保护 故障分析 单相接地 末端线路 zero sequence current protection fault analysis single phase grounding terminal transmission line
  • 相关文献

参考文献12

二级参考文献25

  • 1张红云 ,翟晓凡 ,吴晓蓉 ,谢开贵 .中压配电网可靠性理论计算及分析[J].中国电力,2005,38(6):28-32. 被引量:16
  • 2曾耿晖,黄明辉,刘之尧,唐卓尧,张弛,张哲.同杆线路纵联零序保护误动分析及措施[J].电力系统自动化,2006,30(20):103-107. 被引量:47
  • 3彭向阳 钟定珠.主变压器中性点间隙保护问题分析与建议.南方电网技术研究,2005,1(2):39-43.
  • 4DL/T620—1997.交流电气装置的过电压保护和绝缘配合[S].[S].,..
  • 5DL/T620-1997.交流电气装置的过电压保护和绝缘配合[S].[S].,1997..
  • 6DL755-2001,电力系统安全稳定导则[S],2001.
  • 7GB/T14285-2006,继电保护和安全自动装置技术规程[S].
  • 8Q/GDW156-2006,城市电力网规划设计导则[Z].2006.
  • 9江苏省电力公司,南京供电公司.南京城市电网规划国际咨询成果系列报告[R].2006.
  • 10The System Development Sub-Committee of the Chief Engineers" Conference System Design and Development Committee. The application of engineering recommendation P2/5 security of supply [R]. London, 1979.