阐述了麦园垃圾填埋场清污分流系统存在的问题,分析了渗沥液产生量大等问题的原因。根据工程的实际情况,对存在的问题进行了相应的治理措施设计和实施治理。在今年暴雨量较去年明显偏多的情况下,未再发生渗沥液外溢事故,实践表明,该治理措施在今年汛期起了重要作用。
The paper describes the problems existed in the system of separating clean water from waste water of Maiyuan refuse landfill and analyzes the cause of generating a large amount of leachate. According to the actual condition of the project, and the design and implementation of the relevant control measure are carried out for the existing problems. In case of that the heavy rain this year is obviously more than last year, there is no occurrence of leachate overflow accident, the practice shows that this control measure has played an important role in this flood season.
出处
《有色冶金设计与研究》
2016年第6期40-41,44,共3页
Nonferrous Metals Engineering & Research
关键词
垃圾填埋场
清污分流
渗沥液
截洪沟
覆盖
refuse landfill
separating clean water from waste water
leachate
flood detention ditch
covering