摘要
针对夏热冬暖地区商场过渡季节空调系统运行特点,以广州某商场中央空调冷源系统为研究对象,提出各设备单元的能耗模型,根据空调实际运行数据,利用最小二乘方法对各模型的参数进行辨识,以冷源系统运行设备总能耗最小为目标,探讨基于遗传算法的中央空调冷源系统最佳运行参数值,并将优化的运行参数由动态变量来控制进行实验验证。结果表明:与原运行方式相比,参数优化运行方式下冷源系统节能率为7.07%。
In hot summer and warm winter area, aiming at the operating characteristics of the air-conditioning system of a shopping mall in the transitional season, taking the central air-conditioning cold source system of a shopping mall in Guangzhou as the research object, proposes the energy consumption model of the equipment unit, based on the actual running data of air-conditioning, identifies the parameters of each model by using the least squares method. On this basis, taking the minimum total energy consumption of central air-conditioning cold source system as the goal, obtains the optimum operating parameters of central air-conditioning cold source system based on the genetic algorithm, and the optimized operation parameters are controlled by the dynamic variables to verify the experiment results. The results show that: compared with the original operation mode, the energy saving rate of the cold source system of parameter optimized operation mode is about 7.07%.
作者
闫军威
梁艳辉
黄扬春
喻凡
Yan Junwei Liang Yanhui Huang Yangchun Yu Fan(School of Mechanical & Automotive Engineering, SCUT, Guangzhou, 510641)
出处
《制冷与空调(四川)》
2016年第6期677-683,695,共8页
Refrigeration and Air Conditioning
关键词
商场
过渡季节
空调冷源系统
运行参数
优化
遗传算法
shopping mall
transitional season
central air-conditioning cold source system
operating parameters
optimization
genetic algorithm