摘要
建设在采煤沉陷区的光伏电站,由于其兼具经济效益和社会效益的优势,已成为我国光伏产业发展的重要趋势之一。从光伏电站的工程特点出发,总结了其稳定性问题的特殊性。通过与房屋建筑工程进行比较分析,讨论了评价沉陷区光伏场建设适宜性的分区标准和光伏场对地基稳定性的影响,建议了光伏场设计中的抗采动措施,以期为采煤沉陷区光伏场的稳定性评价和抗采动设计提供相应的参考依据。
The PV station built in coal-mining subsidence area, which has the advantage in both economic benefit and social influence, has become one of the most important mode of PV industry development in China. In this paper, the difference of stability problem between PV station and other projects was summarized based on the characteristic of PV station. After comparing with other ordinary building projects, the evaluation criterion of construction suitability was discussed. In order to provide useful guidance to resist mining deformation, some available measures in PV station design were proposed.