摘要 为了深入研究外浮顶储罐机械密封雷击火花放电点和火花放电电流,加工制作了机械密封雷击实验装置,采用10/350冲击电流开展了机械密封雷击火花放电实验。当机械密封的4个弹片与金属密封板绝缘,冲击电流达到2.12 k A时,密封板与罐壁接触部位、伸缩架与密封板连接处都产生了火花放电现象。当机械密封只有1个弹片与金属密封板接触,冲击电流达到0.578 k A时,弹片与金属密封板之间产生了火花放电。冲击电流达到1.09 k A时,弹片贴合处、伸缩架与密封板连接处都产生了火花放电。由此可见,当储罐遭受雷击时,机械密封存在多处放电点,严重危害着储罐的安全运行。 In order to further study the spark discharge positions and currents of the mechanical seal of external floating roof tank, we processed lightning stroke experiment device of mechanical seal. Lightning stroke experiment of mechanical seal is carried on by 10/350μs impulse current. When it is insulated between four springs and metal sealing plate and impulse current reaches 2.12kA, the spark discharge is generated at contact portion of sealing plate and tank wall, joint of retractable frame and the sealing plate. When only one spring contacts with metal sealing plate, the impact current reaches 0. 578 kA, the shrapnel and metal seal plate produced a spark discharge, and impulse current reached 1.09kA, the spark discharge is generated at contact portion of sealing plate and spring, joint of retractable frame and the sealing plate. These show that there are many discharge points on mechanical seal which seriously endanger safety of tank, when tanks struck by lightning.
出处 《安全、健康和环境》 2016年第12期36-39,共4页 Safety Health & Environment
关键词 外浮顶储罐 机械密封 雷击 火花放电 external floating roof tank mechanical seal lightning stroke spark discharge
  • 相关文献

参考文献9

二级参考文献35

  • 1孙可平,李学文.芯片氧化层静电放电击穿模型研究[J].北京理工大学学报,2005,25(z1):24-27. 被引量:2
  • 2武铜柱.大型立式油罐发展综述[J].石油化工设备技术,2004,25(3):56-59. 被引量:57
  • 3王伶俐,陈春梅.外浮顶油罐密封系统分析[J].油气田地面工程,2004,23(7):25-26. 被引量:14
  • 4唐黎标.惊天霹雳点燃大油库[J].防灾博览,2005(3):36-39. 被引量:2
  • 5周泽存,等.高电压技术[M].中国电力出版社,2007,北京.
  • 6中国石油化工集团公司.GB50074-2002石油库设计规范[S].北京:中国计划出版社.2003.
  • 7GB/T 21714.1-2008/IEC 62305-1:2006雷电防护[S].
  • 8胡海燕 刘宝全 刘全桢 等.浮顶储罐等电位连接装置的雷击阻抗性能探讨.北京理工大学学报,2009,:124-126.
  • 9Liu Quanzhen, Hu Haiyan, Liu Baoquan, et al. A testing research on shunts performance of the large floating storage tanks[C]. The Proceedings of the 6th International Conference on Applied Electrostatics, Shanghai, China, Nov.3-7, 2008: 206-209.
  • 10NFPA 780-2004 standard for the installation of the lightning protection systems[S]. Massachusetts: National Fire Protection Association, 2004.

共引文献85

同被引文献6

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部