期刊文献+

Data Driven CAN Node Reliability Assessment for Manufacturing System 被引量:2

Data Driven CAN Node Reliability Assessment for Manufacturing System
下载PDF
导出
摘要 The reliability of the Controller Area Network(CAN) is critical to the performance and safety of the system. However, direct bus-off time assessment tools are lacking in practice due to inaccessibility of the node information and the complexity of the node interactions upon errors. In order to measure the mean time to bus-off(MTTB) of all the nodes, a novel data driven node bus-off time assessment method for CAN network is proposed by directly using network error information. First, the corresponding network error event sequence for each node is constructed using multiple-layer network error information. Then, the generalized zero inflated Poisson process(GZIP) model is established for each node based on the error event sequence. Finally, the stochastic model is constructed to predict the MTTB of the node. The accelerated case studies with different error injection rates are conducted on a laboratory network to demonstrate the proposed method, where the network errors are generated by a computer controlled error injection system. Experiment results show that the MTTB of nodes predicted by the proposed method agree well with observations in the case studies. The proposed data driven node time to bus-off assessment method for CAN networks can successfully predict the MTTB of nodes by directly using network error event data. The reliability of the Controller Area Network(CAN) is critical to the performance and safety of the system. However, direct bus-off time assessment tools are lacking in practice due to inaccessibility of the node information and the complexity of the node interactions upon errors. In order to measure the mean time to bus-off(MTTB) of all the nodes, a novel data driven node bus-off time assessment method for CAN network is proposed by directly using network error information. First, the corresponding network error event sequence for each node is constructed using multiple-layer network error information. Then, the generalized zero inflated Poisson process(GZIP) model is established for each node based on the error event sequence. Finally, the stochastic model is constructed to predict the MTTB of the node. The accelerated case studies with different error injection rates are conducted on a laboratory network to demonstrate the proposed method, where the network errors are generated by a computer controlled error injection system. Experiment results show that the MTTB of nodes predicted by the proposed method agree well with observations in the case studies. The proposed data driven node time to bus-off assessment method for CAN networks can successfully predict the MTTB of nodes by directly using network error event data.
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第1期190-199,共10页 中国机械工程学报(英文版)
基金 Supported by National Natural Science Foundation of China(Grant No.51475422) Science Fund for Creative Research Groups of National Natural Science Foundation of China(Grant No.51521064) National Basic Research Program of China(973 Program,Grant No.2013CB-035405) Open Foundation of State Key Laboratory of Automotive Safety and Energy,Tsinghua University,China(Grant No.KF13011)
关键词 bus-off MONITORING Controller Area Network industrial automation bus-off, monitoring, Controller Area Network, industrial automation
  • 相关文献

参考文献4

二级参考文献55

  • 1张栾英,李瑞欣,秦志明,谷俊杰.采用模拟退火算法的Elman网络及在热工过程建模中的应用[J].中国电机工程学报,2005,25(11):90-94. 被引量:16
  • 2陈殿生,王田苗,魏洪兴.数控车床故障分布的两重威布尔分段模型[J].北京航空航天大学学报,2005,31(7):766-769. 被引量:22
  • 3阴晓峰,谭晶星,雷雨龙,葛安林.基于神经网络发动机模型的动态三参数换挡规律[J].机械工程学报,2005,41(11):174-178. 被引量:24
  • 4ODVA. Open devicenet vendor association[EB/OL ]. [2010-08-10]. http://www.odva.org/default.aspx?tabid=66.
  • 5Open DeviceNet Venders Association. DeviceNet specifications, 2.0 edition[S]. Ann Arbor, Michigan, USA, 1997.
  • 6LEI Yong, DJURDJANOVIC D, BARAJAS L, et al. DeviceNet network health monitoring using physical layer parameters[J/OL]. Journal of Intelligent Manufacturing[2009-08-09]. http: //www. springerlink.com/content/75r656m00484q75h/.
  • 7FRANK P M, DING X. Survey of robust residual generation and evaluation methods in observer-based fault detection systems[J]. Journal of Process Control, 1997, 7(6): 403-424.
  • 8LIN Along. Hybrid approach to fault diagnosis in network and system management[R]. Palo Alto: Technical report, Hwelett Packard Lab Technical Publ. Dept., 1998.
  • 9SANFORD M, PARISH D, PHILLIPS I. Neural approach to detecting communication network events[J], lEE Proceedings: Communications, 2002, 149(5-6): 257-264.
  • 10KABITZSCH K, KOTTE G, VASYUTYNSKYY V. A monitor tool for cim systems[C]//Proceedings of 2001 IFAC Workshop on Manufacturing, Modeling, Management and Control, Praque, Czech Republic, 2001: 81-85.