期刊文献+

编码超声血流多深度检测 被引量:1

Multi-depth blood flow detection based on coding ultrasound technique
下载PDF
导出
摘要 血流信息检测及其成像因其独特的优势,在临床上得到广泛应用。但常规经颅多普勒超声系统仍采用模拟和数字电路结合的传统技术,这类系统容易受到外界干扰且不能进行多深度检测。文章设计出一种全数字多普勒超声血流检测系统方案,弥补了传统模拟系统存在的问题。多普勒仿体和人体实验结果表明,该系统能够进行多深度检测,确定血管的深度;同时,还提高了检测灵敏度、超声穿透力和系统成像分辨率。 Blood flow measurement and imaging are important branches in ultrasound diagnostic system. Because of its unique advantages, it has been widely used in clinical departments. However, conventional Transcranial Doppler (TCD) ultrasound system in domestic markets still uses the traditional technology combined with analog and digital circuits. Such instruments are susceptible to external changes and cannot offer a multi-depth examination. In this study, a multi-depth digital design of TCD ultrasound system is introduced, which can make up for the deficiency of the traditional analog system to achieve a multi-depth inspection and to enhance the detection sensitivity, the average penetration capacity and resolution of the system. The feasibility of the system is proved by the phantom test, pump and clinical experiments. All of the results show that the system could display the blood flow information on the path of the ultrasound wave, detect the vessel positioning. Meanwhile, it also can greatly improve the measurement sensitivity.
出处 《声学技术》 CSCD 北大核心 2016年第6期527-530,共4页 Technical Acoustics
基金 深圳市海外高层次人才创新创业专项资金研发项目(KQC201105310020A)
关键词 编码激励 经颅多普勒超声 多深度检测 coded excitation Transcranial Doppler (TCD) multi-depth examination
  • 相关文献

参考文献3

二级参考文献43

  • 1Jensen J A, Nikolov S I. Directional synthetic aperture flow imaging [J]. IEEE Trans Ultrason Ferroelect Freq Contr, 2004, 51: 1107-1118.
  • 2ZHAO Heng, MO Larry Y L, GAO Shangkai. Barker-coded ultrasound color flow imaging: Theoretical and practical design considerations [J]. IEEE Trans Ultrason Ferroelect Freq Contr, 2007, 54: 319-331.
  • 3Chiao R Y, Hao X. Coded excitation for diagnostic ultrasound: A system developer's perspective [J]. IEEE Trans Ultrason Ferroelect Freq Contr, 2005, 52 : 160 - 170.
  • 4Jensen J A, Svendsen N B. Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers [J]. IEEE Trans Ultrason Ferroelec Freq Contr, 1992, 39: 262-267.
  • 5Golay M J E. Complementary series [J]. IRE Trans Info Theory, 1961, IT-7: 82-87.
  • 6Welch L R, Fox M D. Practical spread spectrum pulse compression for ultrasonic tissue imaging [J]. IEEE Trans Ultrason Ferroelect Freq Contr, 1998, 45 : 349 - 355.
  • 7Ruprecht J, Rupf M. On the search for good aperiodic binary invertible sequences [J]. IEEE Tram Info Theory, 1996, 42: 1604- 1612.
  • 8LIU Kai, GAO Shangkai. Searching binary sequences for coded excitation in medical ultrasound [C]//Proc IEEE Eng Med Biol Conf. Shanghai: IEEE Press, 2005 : 1858 - 1860.
  • 9Misaridis T X, Gemmelmark K, Jorgensen C H, et al. Potential of coded excitation in medical ultrasound imaging [J]. Ultrasonics, 2000, 38: 183- 189.
  • 10Muzilla D J, Chiao R Y, Hall A L. Method and apparatus for color flow imaging using coded excitation with single codes: US, 5,938,611 [P]. 1999.