为了降低大容量设备能耗测试的成本和难度,简化测试工作,在传统测试方法的基础上,通过分析历史测试数据,研究了电源转化率稳定后业务板卡与整机能耗的线性模型,提出了大容量通信设备能耗测试的简易方法,并经过实验室测试验证了该方法的可行性。
In order to reduce the cost and difficulty of large capacity equipment energy consumption test and simplify the testing work, the traditional testing method was analyzed in this paper. Based on the historical data of the energy consumption test, the linear model of service card and equipment energy consumption in the case of the stable power conversion rate was studied to propose a simple method of the energy consumption test for the large capacity communication equipment. Laboratory tests validate the feasibility of the proposed method.
作者
李韶英
庄湛海
陈昊
LI Shao-ying ZHUANG Zhan-hait CHEN Hao(Guangdong Research Institute of China Tdecom Co.. Ltd., Guangzhou 510630, China Guangzhou Useease Information Technology Co., Ltd., Guangzhou 510630, China)
出处
《移动通信》
2017年第1期58-62,共5页
Mobile Communications
关键词
大容量设备
能耗测试
电源转化率
large capacity equipment energy consumption test power conversion rate