期刊文献+

无创冷冻融脂临床疗效及安全性评估

Clinical efficacy and safety evaluation of non-invasive selective cryolipolysis
下载PDF
导出
摘要 目的 评价无创冷冻融脂的临床疗效及安全性。 方法 收集2014年4—10月首都医科大学附属北京安贞医院收治的16例无创冷冻融脂受试者,在治疗前、治疗后3个 月行治疗部位磁共振扫描,记录包括脂肪含量百分比、脂肪厚度等影像学数据及其他非影像学的主客观评价数据,对无创冷冻融脂的疗效和安全性进行评价。 结果 治疗有效 率评价,医生评价为81.2%(13/16),受试者自评为75.0%(12/16),二者差异无统计学意义(P〉0.05)。治疗后治疗区脂肪厚度明显低于治疗前,差异有统计学意义[(2.3± 0.4)cm比(3.0±0.5)cm](P〈0.01);治疗前后治疗部位脂肪含量百分比差异无统计学意义(P〉0.05)。无严重不良反应发生。 结论 无创冷冻融脂能安全、有效地减少皮 下脂肪厚度,达到减脂塑形的目的。 Objective To evaluate the clinical efficacy and safety of non-invasive selective cryolipolysis. Methods A total of 16 patients who had non-invasive selective cryolipolysis from April 2014 to October 2014 in Beijing Anzhen Hospital, Capital Medical University were enrolled. Magnetic resonance scan was performed before and 3 months after treatment to record fat percentage and thickness. The effective rate of treatment and adverse reactions were analyzed.ResultsThe subjective effective rate was 81.2%(13/16) and the objective effective rate was 75.0%(12/16), the difference was not significant(P〉 0.05). The fat thickness after treatment was significantly decreased compared to that before treatment[(2.3±0.4)cm vs (3.0±0.5)cm](P〈0.01). There was no significant difference of fat percentage before and after treatment(P〉0.05). No severe adverse events were observed. Conclusion Non-invasive cryolipolysis can effectively reduce the subcutaneous fat thickness with good safety.
出处 《中国医药》 2017年第1期139-141,共3页 China Medicine
关键词 冷冻融脂 无创 脂肪定量分析 安全性 Cryolipolysis Non-invasive Fat quantitative analysis Safety
  • 相关文献

参考文献3

二级参考文献53

  • 1张兆清,余春艳,金岩,董高宏,聂鑫,刘鹏,赵宇,胡世颉.复合骨髓间充质干细胞的组织工程皮肤治疗慢性难愈性溃疡探讨[J].中国皮肤性病学杂志,2006,20(4):211-213. 被引量:12
  • 2Bernard CP,Liney GP,Manton DJ,et al.Comparison of fat quantification methods:a phantom study at 3.0 T[J].J Magn Reson I maging,2008,27:192-197.
  • 3Kühn JP,Evert M,Friedrich N,et al.Noninvasive quantification of hepatic fat content using three-echo dixon magnetic resonance imaging with correction for T2* relaxation effects[J].Invest Radiol,2011,46:783-789.
  • 4Hussain HK,Chenevert TL,Londy FJ,et al.Hepatic fat fraction:MR imaging for quantitative measurement and display-early experience[J].Radiology,2005,237:1048-1055.
  • 5Yu H,Shimakawa A,Hines CD,et al.Combination of complex-based and magnitude-based multiecho water-fat separation for accurate quantification of fat-fraction[J].Magn Reson Med,2011,66:199-206.
  • 6Bydder M,Yokoo T,Hamilton G,et al.Relaxation effects in the quantification of fat using gradient echo imaging[J].Magn Reson Imaging,2008,26:347-359.
  • 7Ma J.Dixon techniques for water and fat imaging.J Magn Reson Imaging,2008,28:543-558.
  • 8Cassidy FH,Yokoo T,Aganovic L,et al.Fatty liver disease:MR imaging techniques for the detection and quantification of liver steatosis[J].Radiographics,2009,29:231-260.
  • 9Hijona E,Sánchez-González J,Alústiza JM,et al.Accurate fat fraction quantification by multiecho gradient-recalled-echo magnetic resonance at 1.5 T in rats with nonalcoholic fatty liver disease[J].Eur J Radiol,2012,81:1122-1127.
  • 10Liu CY,McKenzie CA,Yu H,et al.Fat quantification with IDEAL gradient echo imaging:correction of bias from T(1) and noise[J].Magn Reson Med,2007,58:354-364.

共引文献50