超声膀胱测容仪在盆腔肿瘤放疗中的应用进展 被引量:10

Application Progress of Ultrasound Bladder-Scan in Pelvic Tumor Radiotherapy
下载PDF
导出
摘要 放射治疗(放疗)过程中膀胱体积的变化是制约盆腔恶性肿瘤实现精确放疗的关键。目前常用的依赖人体生物反馈法憋尿不能满足精确放疗的要求,使用导尿管进行人工膀胱充盈则为有创操作,不良反应明显。超声膀胱测容仪可快速计算出人体膀胱容量,其准确性高、操作简单,可有效监测和管理膀胱充盈度,确保放疗时膀胱体积在目标范围内,减少盆腔内器官及靶区的位移,实现盆腔恶性肿瘤的精确放疗。 The change of the bladder volume during radiation treatment is the key to achieve precise radiotherapy of pelvic tumor. Depending on human body biological feedback to keep bladder stable is the common method, but it cannot meet the requirements of precise radiotherapy. Using catheter to fill bladder artificially is worse for body. The ultrasound bladder e-scan can calculate the volume of the bladder quickly and accurately. It's easy to operate, and to ensure the bladder volume within the scope of the requirements, if we use it before each radiation therapy. And then the precise radiotherapy of pelvic tumor could be realized by reducing the displacement of the organ and the radiation field in the pelvic cavity.
作者 杨丁懿 万跃 周宪 罗焕丽 靳富 王颖 YANG Dingyi WAN Yue ZHOU Xian LUO Huangli JIN Fu WANG Ying.(Department of Radiation Oncology , Chongqing Cancer Institute/Hospital/Cancer Center, Chongqing 400030, Chin)
出处 《医学综述》 2017年第1期50-53,共4页 Medical Recapitulate
基金 国家自然科学基金(11575038) 重庆市肿瘤研究所新技术新项目(2016-6)
关键词 盆腔肿瘤 超声膀胱测容仪 放射治疗 Pelvic tumor Ultrasound bladder-scan Radiotherapy
  • 相关文献

参考文献8

二级参考文献83

  • 1刘跃平,刘新帆,李晔雄,金晶,关莹.前列腺癌三维适形放疗中体位对靶区和正常组织体积及照射剂量的影响[J].中华放射肿瘤学杂志,2005,14(5):422-426. 被引量:12
  • 2Turan OM,Turan S,Funai EF,et al.Fetal adrenal gland volume:a novel method to identify women at risk for impending preterm birth.Obstet Gynecol,2007,109(4):855-862.
  • 3Kelly CE.Evaluation of voiding dysfunction and measurement of bladder volume.Rev Urol,2004,6 Suppl 1:S32-37.
  • 4Grison A,Maschietto N,Reffo E,et al.Three-dimensional echocardiographic evaluation of right ventricular volume and function in pediatric patients:validation of the technique.J Am Soc Echocardiogr,2007,20(8):921-929.
  • 5Raine-Fenning N,Campbell B,Collier J,et al.The reproducibility of endometrial volume acquisition and measurement with the VOCAL-imaging program.Ultrasound Obstet Gynecol,2002,19(1):69-75.
  • 6Mell LK, Roeske JC, Mundt AJ. A survey of intensity modulated radiation therapy use in the United States. Cancer,2003,98:204- 211.
  • 7Roeske JC, Lujan A, Rotmensch J, et al. Intensity-modulated whole pelvic radiation therapy in patients with gynecologic malignancies. Int J Radiat Oncol Biol Phys ,2000 ,48 :1613-1621.
  • 8Mell LK, Tiryaki H, Ahn KH, et al. Dosimetric comparison of bone marrow-sparing intensity-modulated radiotherapy versus conventional techniques for treatment of cervical cancer. Int J Radiat Oncol Biol Phys,2008,71:1504-1510.
  • 9Chen MF, Tseng C J, Tseng CC, et al. Clinical outcome in post hysterectomy cervical cancer patients treated with concurrent cisplatin and intensity-modulated pelvic radiotherapy: comparison with conventional radiotherapy. Int J Radiat Oncol Biol Phys, 2007,67 : 1438-1444.
  • 10Chan P, Dinniwell R, Haider MA, et al. Inter-and intrafractional tumor and organ movement in patients with cervical cancer undergoing radiotherapy: a cinematic-MRI point-of-interest study. Int J Radiat Oncol Biol Phys ,2008,70 : 1507-1515.

共引文献99