摘要
介绍了导体的自阻与互阻的计算方法,分析了接地网不等电位的数学模型。通过节点电压法,得到按照指数函数规律布置接地导体可以降低接地网接触电压的结论。结果表明:采用不等间距布置方法可以使得电位分布更加均匀,确保人身安全与系统可靠的运行。
Introduction was made to the calculation method of self-resistance and mutual resistance. This paper analyzed the mathematical model of the grounding grid with unequal potential. The node voltage method was used to conclude that the arranged grounding conductor could reduce the contact voltage of the grounding grid according to the exponential function rule. The results show that the unequal spacing method can make the potential distribution more uniform and ensure the personal safety and the reliable operation of the system.
作者
王成
葛强
徐燕
耿梦儒
谬利蓉
WANG Cheng GE Qiang XU Yan GENG Meng-ru MIU Li-rong(School of Hydraulic, Energy and Power Engineering, Yangzhou University, Yangzhou 225127, China)
出处
《电工电气》
2017年第1期22-25,共4页
Electrotechnics Electric
关键词
接地网
节点电压法
接触电压
不等电位
不等间距
grounding grid
node voltage method
contact voltage
unequal potential
unequal spacing