摘要
利用荧光胺与盐酸美西律的芳伯胺基生成高度荧光衍生物,检测盐酸美西律片盐酸美西律的含量。实验表明荧光胺与盐酸美西律的芳伯胺基生成的荧光衍生物的最大激发波长为397nm,最大发射波长为387nm。利用L9(34)正交试验确定了最佳衍生条件:反应温度25℃,反应时间20min,衍生剂加入量2.60 m L。盐酸美西律含量在0.0160μg·m L^(-1)~0.800μg·m L^(-1)的浓度范围内与相对荧光强度存在线性关系,线性方程为y=3809.4x+2024.1,线性相关系数为0.998,此法可用于检测盐酸美西律片盐酸美西律的含量。
Mexiletine hydrochloride in mexiletine hydrochloride tablets was detemined with high fluorescent derivatives generated from mexiletine hydrochloride and fluorescent amine.Experiments showed that tmaximum excitation wavelength at 397 nm and a maximum emission wavelength of 387 nm.The optimal derivatization conditions were determined by L9( 34) orthogonal experiment as follows: derivative temperature 25℃,time 20 min,and fluoresamin( 0. 200mg·m L^-1) addition 2. 60 m L.Mexiletine hydrochloride content in the concentration range of 0. 0160μg·m L^-1- 0. 800μg·m L^-1and relative fluorescence intensity are linear relationship,linear equations for y = 3809. 4x+2024. 1,linear correlation coefficient is 0. 998. This method can be used to detect mexiletine hydrochloride in mexiletine hydrochloride tablets.
出处
《化学研究与应用》
CAS
CSCD
北大核心
2017年第1期94-98,共5页
Chemical Research and Application
基金
山东省教育厅课题(J16LC51)资助
关键词
荧光分光光度法
盐酸美西律
荧光胺
正交试验
fluorescence spectrophotometry
mexiletine hydrochloride
fluorescent amine