期刊文献+

大空间温度场预测模型与实验分析 被引量:3

Large space temperature field prediction model and experimental analysis
下载PDF
导出
摘要 介绍国内三个大空间温度场预测模型。通过在某高大钢结构厂房内进行大空间小功率油池火实验,得到火焰正上方4.0m和7.5m处的温度变化情况。将实验结果与三个预测模型的预测结果进行对比,结果表明:三个模型都能较好地预测出火源正上方4.0m处温度变化的趋势;只有张国维公式给出了火灾全过程预测;薛素铎公式能够很好地展现增长阶段到稳定阶段的过渡过程;对7.5m处的预测结果偏差较大;三个公式都对最大温度值有较强的依赖性。 Three large space temperature field prediction models in China were introduced.In a tall steel structure workshop,fire experiments of small power oil pool in large space were conducted,getting the temperature variation at 4.0mand 7.5mabove fire source.The experimental data and the calculation results were compared,and the results showed that,3models all can predict the temperature 4.0 mabove the fire source well;only the formula from ZHANG Guo-wei can predict the whole process of fire;formula from XUE Su-duo can show the transient process from developing stage to stable stage well;the prediction of temperature 7.5 mabove the fire source had big error;the three model all rely on maximum temperature value strongly.
作者 于志超 朱国庆 田承飞 YU Zhi-chao ZHU Guo-qing TIAN Cheng-fei(Faculty of Safety Engineering, China University of Mining and Technology, Jiangsu Xuzhou 221116, China Key Laboratory of Gas and Fire Control for Coal Mines, China University of Mining and Technology, Jiangsu Xuzhou 221116, China Fire Research Institute, China University of Mining and Technology, Jiangsu Xuzhou 221116, China)
出处 《消防科学与技术》 CAS 北大核心 2016年第10期1372-1375,共4页 Fire Science and Technology
基金 江苏省自然科学基金项目(BK20131117)
关键词 高大空间 火源 温度场 预测模型 large space fire source temperature field prediction model
  • 相关文献

参考文献6

二级参考文献23

  • 1李国强,杜咏.实用大空间建筑火灾空气升温经验公式[J].消防科学与技术,2005,24(3):283-287. 被引量:76
  • 2白音,石永久,王元清.火灾下大空间结构温度场的数值模拟分析[J].中国安全科学学报,2006,16(1):34-38. 被引量:30
  • 3梅宁,尹凤,陆虹涛.湿度变化对气体污染物扩散影响的研究[J].中国海洋大学学报(自然科学版),2006,36(6):987-990. 被引量:15
  • 4李国强 蒋首超 林桂祥.钢结构抗火计算与设计[M].北京:中国建筑工业出版社,1996..
  • 5Technical Memoranda (TM19: 1995), Relationships for smoke control calculations[S]. The Chartered Institution of Building Services Engineers.
  • 6李国强,蒋首超, 林桂祥. 钢结构抗火计算与设计[M].北京:中国建筑工业出版社,1996.
  • 7John H Klote. Method of predicting smoke movement in atria with application to smoke management NISTIR 5516[S], November 1994.
  • 8ZHANC; Fu ten, ZHANG Hui, LONGJiao. CFDnumericalsimu lation on three dimensions diffusion concentration field of indoor gas leakage[C]//ICSCRM 2010. Chongqing : 2010.
  • 9Shok A Luhar K. Analytical puff modelling of light wind dispersion in stable and unstable conditions[J]. Atmospheric Environment. 2011,45:357 -368.
  • 10Scargiali F, Rienzo E Di,Ciofalo M. Heavy gas dispersion modelling over a topographically complex mesoscale-- A CFI) based approach [J]. Process Safety and Environmental Protection, 2005,83(B3) : 242--256.