期刊文献+

正电子发射断层扫描标准摄取值及其在肿瘤诊断中的应用进展 被引量:8

Review of Progress of PET SUV in Tumor Diagnosis
下载PDF
导出
摘要 临床中PET-CT作为一种新型的非损伤性的诊断技术,能提供功能与解剖相结合的影像资料,现多用于肿瘤的诊疗。标准化摄取值(SUV)作为PET-CT中应用最为广泛的半定量分析指标,其对不同肿瘤良恶性鉴别诊断的界值将影响着最终的诊断结果、后续的治疗方案以及预后情况。对SUV的影响因素、校正方案以及利用SUV对不同肿瘤进行鉴别诊断的界值及其进展加以综述。尽管SUV对肿瘤的诊断没有公认的界值,但仍然是肿瘤诊断中重要的半定量指标。在临床工作中合理谨慎利用SUV进行诊断分析,可提高肿瘤诊断的灵敏度及特异度。 Whole-body PET-CT scanning has been used in the diagnosis and treatment of tumor to providing functional and morphological imaging. As the most widely used semiquantitative analysis index, the cutoff value of SUV would affect the final diagnosis, therapeutic regimen and prognosis estimation. Therefore, the article reviews the influential factors of SUV, its correction methods, its cutoff values of differential various tumors and the progress of SUV. Although there is no acknowledged cutoff value of SUV in tumor diagnosis, SUV is still an important semi-quantitative index, and its rational and prudent use would increase both of the sensitivity and specificity in tumor diagnosis.
机构地区 北京协和医学院
出处 《中国医学装备》 2017年第1期117-121,共5页 China Medical Equipment
基金 国际科技合作项目(2009DFA32960)“PET/CT脑分子影像研究与应用平台及针灸中枢机理探索” 中国癌症基金会北京希望马拉松专项基金(LC2013A13和LC2016A02)“PET/CT的辐射剂量和图像质量的模型研究”和“PET/CT及SPECT、SPECT/CT受检者辐射剂量的研究”
关键词 正电子发射断层摄影术 体层摄影术 标准摄取值 肿瘤 Positron-emission tomography Tomography Standard uptake value Tumor
  • 相关文献

参考文献9

二级参考文献107

  • 1陈英茂,耿建华,田嘉禾,尹大一,姚树林,陈盛祖.正电子发射断层扫描图像部分容积效应的模拟研究及实验检验[J].原子能科学技术,2004,38(5):467-473. 被引量:6
  • 2耿建华,陈英茂,陈盛祖,田嘉禾,何义杰,乔士珍.符合线路显像与PET显像中SUV的比较研究[J].中华核医学杂志,2004,24(5):308-309. 被引量:11
  • 3吴湖炳,王全师,王明芳,王欣璐,郭晓君.鼻咽癌PET/CT影像表现及临床价值[J].中华核医学杂志,2005,25(6):347-349. 被引量:22
  • 4Lenders K,Perani D,Lammertsma A,et al.Cerebral blood flow,blood volume and oxygen utilization[J].Normal values and effect of age.Brain,1990,113:27-47.
  • 5Marchal G,Rioux P,Petit-Taboue M-C,et al.Regional cerebral oxygen consumption,blood flow,and blood volume in healthy human aging[J].Arch Neurol,1992,49:1013-1020.
  • 6Meltzer CC,Cantwell MN,Greer PJ,et al.Does cerebral blood flow decline in healthy aging? A PET study with partial-volume correction[J].Nucl Med,2000,41:1842-1848.
  • 7Giovacchini G,Lerner A,Toczek MT,et al.Brain incorporation of 11C-arachidonic acid,boold volume,and blood flow in healthy aging:a study with partial-volume correction[J].Nucl Med,2004,45:1471-1479.
  • 8Frouin V,Comtat C,Reilhac A,et al.Correction of Partial Volume Effect for PET Striatal Imaging:Fast Implementation and Study of Robusmess[J].Nucl Med,2002,43:1715-1726.
  • 9Bencherif B,Stumpf MJ,Links JM,et al.Application of MRI-based partial-volume correction to the analysis of PET images of u-opioid receptors using statistical parametric mapping[J].Nucl Med,2004,45:402-408.
  • 10Quarantelli M,Berkouk K,Prinster A,et al.Integrated software for the analysis of brain PET/SPECT studies with partial-volume-dffect correction[J].Nucl Med,2004,45:192-201.

共引文献65

同被引文献96

引证文献8

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部