期刊文献+

三电极系统处理含藻水 被引量:1

Treatment of algae-laden water by three electrodes system
原文传递
导出
摘要 以铝、掺硼金刚石为阳极,不锈钢为阴极构建三电极系统处理含藻水,考察了电流密度、通电时间、沉降时间、初始pH、极板间距对处理效果的影响。结果表明,各因素对藻的去除率的影响顺序为:电流密度>通电时间>沉降时间>初始pH>极板间距,而且电流密度2 m A·cm^(-2),通电时间为30 min,沉降时间为15 min,pH=6,极板间距取1.0 cm为实验的最优工况点。 Anti-algal water treatment was conducted in a three-electrode system using aluminum and borondoped diamond as the anode and stainless steel as the cathode. The effects of the operating parameters,such as current density,electrolysis time,initial pH,setting time,and electrode gap were studied. The results revealed that the ordering of these factors in terms of the strength of their effect on the algae removal efficiency is as follows: current density 〉electrolysis time 〉setting time 〉initial pH 〉electrode gap. The optimal operating conditions were identified as a current density of 2 m A·cm^-2,electrolysis time of 30 min,setting time of 15 min,initial pH of 6,and electrode gap of 10 mm.
作者 向平 方宇 张亚晴 XIANG Ping FANG Yu ZHANG Yaqing(Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment, Ministry of Education, Chongqing University, Chongqing 400045, Chin)
出处 《环境工程学报》 CAS CSCD 北大核心 2017年第2期793-797,共5页 Chinese Journal of Environmental Engineering
基金 中央高校基本科研业务费(106112012CDJZR210013)
关键词 电化学 铜绿微囊藻 掺硼金刚石 三电极系统 electrochemistry microcystis aeruginosa aluminum boron-doped diamond three electrodes system