期刊文献+

Numerical Study of Unsteady Flows with Cavitation in a High-Speed MicroCentrifugal Pump 被引量:9

Numerical Study of Unsteady Flows with Cavitation in a High-Speed Micro Centrifugal Pump
原文传递
导出
摘要 The unsteady flows caused by the interaction between the impeller and the volute in a high-speed micro centrifugal pump are numerically studied. The internal flows of both with and without cavitations are analyzed using the CFX. The characteristics of unsteady pressure on the blade surfaces and the symmetric plane of the volute are presented and compared. The results show that the amplitudes of pressure fluctuations of critical cavitation on the blade pressure surface(PS) are bigger as compared with those at the non-cavitation condition, but on the suction surface(SS), the situation is on the contrary. When cavitation occurs, reduction of load in the impeller is a result. In the present study, such reduction of load is observed mainly on the first half of the blades. Pressure fluctuations at five monitoring points, denoted by WK1 to WK5 in the volute, are also analyzed. No matter at the critical cavitation or at the non-cavitation conditions, the monitored pressure fluctuations are at the same frequencies, which equal to the blade passing frequency(BPF) and its multiples. However, the amplitudes of the fluctuations at critical cavitation condition are considerably stronger, as compared with those for without cavitation. The unsteady flows caused by the interaction between the impeller and the volute in a high-speed micro centrifugal pump are numerically studied. The internal flows of both with and without cavitations are analyzed using the CFX. The characteristics of unsteady pressure on the blade surfaces and the symmetric plane of the volute are presented and compared. The results show that the amplitudes of pressure fluctuations of critical cavitation on the blade pressure surface (PS) are bigger as compared with those at the non-cavitation condition, but on the suction surface (SS), the situation is on the contrary. When cavitation occurs, reduction of load in the impeller is a result. In the present study, such reduction of load is observed mainly on the first half of the blades. Pressure fluctuations at five monitoring points, denoted by WK1 to WK5 in the volute, are also analyzed. No matter at the critical cavitation or at the non-cavitation conditions, the monitored pressure fluctuations are at the same frequencies, which equal to the blade passing frequency (BPF) and its multiples. However, the amplitudes of the fluctuations at critical cavitation condition are considerably stronger, as compared with those for without cavitation. © 2017, Science Press, Institute of Engineering Thermophysics, CAS and Springer-Verlag Berlin Heidelberg.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2017年第1期18-24,共7页 热科学学报(英文版)
基金 funded by the National Natural Science Foundation of China under Grants 51176048 and 51576067
关键词 Micro-centrifugal pump UNSTEADY flow Cavitation Pressure fluctuation. Centrifugal pumps Impellers Pumps Unsteady flow
  • 相关文献

同被引文献65

引证文献9

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部