摘要 为了减小测站间时间同步偏差对多测站激光测距的影响,提高空间碎片的测定轨精度,探讨了利用GPS共视法近实时地实现测站间高精度时间同步的方法。实验选取激光测站长春站(CHAL)和日本鹿儿岛站GUTS Masda(GMSL)进行时间同步实验,并用后处理的IGS精密钟差产品对计算结果进行了验证。该方法的时间同步精度达3 ns(RMSE),可满足多测站激光测距对时间同步精度的需求。 In order to reduce the influence of time synchronization deviation between observation stations on the multi-station laser ranging and improve the orbit-determination precision for space debris, we discussed a method based on GPS common view for realizing the high-precision time synchronization between stations almost in real time. The Changchun station (CHAL) and GUTS Masda station (GMSL) were chosen to conduct the time synchronization experiment, and the calculated results are compared with IGS clock-difference product. The result shows that the precision of time synchronization for this method is 3 nanoseconds, meeting the needs of multi-station laser ranging in time synchronization.
作者 陈东隅 张子昂 范存波 CHEN Dong-yu ZHANG Zi-ang FAN Cun-bo(Changchun Observatory, National Astronomical Observatories, Chinese Academy of Sciences, Changchtm 130117, China University of Chinese Academy of Sciences, Beijing 100049, China)
出处 《时间频率学报》 CSCD 2016年第4期282-289,共8页 Journal of Time and Frequency
基金 国家自然科学基金资助项目(11103047) 中国科学院精密导航定位与定时技术重点实验室开放基金资助项目(2014PNTT10)
关键词 多测站卫星激光测距 时间同步 GPS共视法 multi-station laser ranging time synchronization GPS common view
  • 相关文献

参考文献4

二级参考文献30

  • 1章红平,平劲松,朱文耀,黄珹.电离层延迟改正模型综述[J].天文学进展,2006,24(1):16-26. 被引量:83
  • 2李志刚,程宗颐,冯初刚,李伟超,李慧茹.电离层预报模型研究[J].地球物理学报,2007,50(2):327-337. 被引量:64
  • 3[6]Lewandowski W, Petit C, Thomas C, et al. (1990) The use of precise ephemerides, ionospheric data and corrected antenna coordinates in a long-distance GPS time transfer. The 22nd Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, Vienna, VA.
  • 4[7]Lewandowski W, Azoubib J, Klepczynski W (1999) GPS: primary tool for time transfer. IEEE, (99): 431-434
  • 5[8]Kouba J, Springer T (2001) New IGS station and satellite clock combination. GPS Solutions, 4(4):31-36
  • 6[9]Allan D W (1998) New timing opportunities with GPS. GPS Solutions, 2(1):27-35
  • 7[10]Defraigne P, Bruyninx C (2001) Time transfer for TAI using a geodetic receiver, an example with the ashtech ZXII-T. GPS Solutions, 5(2): 43-50
  • 8[11]Defraigne P, Petit G (2001) Proposal to use geodetic-type receivers for time transfer using the CGGTTS format. BIPM Time Section Technical Memorandum, (TM) 110.
  • 9[12]Defraigne P, Bruyninx C, Clarke J, et al. (2001) Time transfer to TAI with geodetic receivers. Symposium of EFTF, Neuchatel.
  • 10[13]Chao Y C (1997) Real time implementation of the wide area augmentation system for the global positioning system with an emphasis on ionospheric modeling:[ Ph.D dissertation]. San Francisco: Sanford University.

共引文献13

同被引文献26

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部