期刊文献+

Clinical value of contrast-enhanced ultrasound in improving diagnostic accuracy rate of transthoracic biopsy of anteriormedial mediastinal lesions 被引量:6

Clinical value of contrast-enhanced ultrasound in improving diagnostic accuracy rate of transthoracic biopsy of anteriormedial mediastinal lesions
下载PDF
导出
摘要 Objective: To evaluate the clinical value of contrast-enhanced ultrasound(CEUS) in transthoracic biopsy of anterior-medial mediastinal lesions.Methods: A total of 123 patients with anterior or middle mediastinum lesions required ultrasound guided transthoracic biopsy for pathological diagnosis. Among them, 72 patients received CEUS examinations before biopsy. After CEUS, 8 patients were excluded from biopsy and the rest 64 patients underwent biopsy(CEUS group). During the same period, 51 patients received biopsy without CEUS examination(US group). The ultrasonography characteristics, the number of biopsy puncture attempts, diagnostic accuracy rate and the incidence of complications were recorded and compared between the two groups.Results: A large portion of necrosis area or superficial large vessels was found in 8 patients, so the biopsy was cancelled. The internal necrosis was demonstrated in 43.8% of the lesions in CEUS group and in 11.8% of US group(P0.001). For thymic carcinoma, CEUS increased the detection rate of internal necrosis and pericardial effusion than conventional ultrasound(62.5% vs. 18.8%, P=0.012; 56.3% vs. 12.5%, P=0.023). The average number of punctures in CEUS group and US group was 2.36±0.70 and 2.21±0.51 times, respectively(P0.05). The diagnostic accuracy rate of biopsy in CEUS group(96.9%, 62/64) was significantly higher than that in US group(84.3%, 43/51)(P=0.022). In US group, 2 patients suffered from mediastinal bleeding(3.9%), while no major complications occurred in CEUS group.Conclusions: CEUS examination provided important information before transthoracic mediastinum biopsy and improved diagnostic accuracy rate in biopsy of anterior and middle mediastinum lesions than conventional ultrasound. Objective: To evaluate the clinical value of contrast-enhanced ultrasound(CEUS) in transthoracic biopsy of anterior-medial mediastinal lesions.Methods: A total of 123 patients with anterior or middle mediastinum lesions required ultrasound guided transthoracic biopsy for pathological diagnosis. Among them, 72 patients received CEUS examinations before biopsy. After CEUS, 8 patients were excluded from biopsy and the rest 64 patients underwent biopsy(CEUS group). During the same period, 51 patients received biopsy without CEUS examination(US group). The ultrasonography characteristics, the number of biopsy puncture attempts, diagnostic accuracy rate and the incidence of complications were recorded and compared between the two groups.Results: A large portion of necrosis area or superficial large vessels was found in 8 patients, so the biopsy was cancelled. The internal necrosis was demonstrated in 43.8% of the lesions in CEUS group and in 11.8% of US group(P0.001). For thymic carcinoma, CEUS increased the detection rate of internal necrosis and pericardial effusion than conventional ultrasound(62.5% vs. 18.8%, P=0.012; 56.3% vs. 12.5%, P=0.023). The average number of punctures in CEUS group and US group was 2.36±0.70 and 2.21±0.51 times, respectively(P0.05). The diagnostic accuracy rate of biopsy in CEUS group(96.9%, 62/64) was significantly higher than that in US group(84.3%, 43/51)(P=0.022). In US group, 2 patients suffered from mediastinal bleeding(3.9%), while no major complications occurred in CEUS group.Conclusions: CEUS examination provided important information before transthoracic mediastinum biopsy and improved diagnostic accuracy rate in biopsy of anterior and middle mediastinum lesions than conventional ultrasound.
出处 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2016年第6期617-625,共9页 中国癌症研究(英文版)
基金 supported by Beijing Municipal Health System Special Funds of High-Level Medical Personnel Construction (No. 2013-3-086) the Natural Science Foundation of Beijing (No. 7152031) Beijing Baiqianwan Talents Project
关键词 BIOPSY contrast-enhanced ultrasound(CEUS) diagnostic accuracy rate MEDIASTINAL Biopsy contrast-enhanced ultrasound(CEUS) diagnostic accuracy rate mediastinal
  • 相关文献

参考文献1

二级参考文献1

共引文献7

同被引文献25

引证文献6

二级引证文献80

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部