摘要
在详细分析核岛厂房通风系统的用冷特点及其溴化锂机组优缺点的基础上,对以汽轮机蒸汽作为气源的溴化锂机组为核岛厂房供冷的可行性进行了分析,得出了以汽轮机抽气作为气源的溴化锂制冷机组无法独立为核岛厂房供冷的结论。
Analyses the cooling load characteristics of the nuclear island building ventilation system and the advantages and disadvantages of LiBr absorption chiller, using turbine steam as source, discusses the practicability of the steam-LiBr chiller and supplying chilled water for the nuclear island. The results show that the LiBr chiller cannot supply chilled water for the nuclear island independently.
出处
《暖通空调》
北大核心
2017年第2期26-28,共3页
Heating Ventilating & Air Conditioning
关键词
核电厂
溴化锂
冷水
核岛
汽轮机
nuclear power plant, LiBr, chilled water, nuclear island, steam turbine