摘要
介绍RIK140-1+1+1+1型离心式空气压缩机的故障问题,通过分析排查,确认其故障原因是静电腐蚀导致的。采取相应措施予以处理,实现了压缩机的长周期安全稳定运行。
RIK140-1+l+l+l type centrifugal air compressor malfunction was described in this paper. Study and survey shows that the malfunction was caused by static corrosion. Corresponding measures were tak- en to realize the safe and stable operation of air compressor for a long period of time.
作者
李恒远
王建龙
Li Hengyuan Wang Jianlong(SINOPEC Jinling Branch, NanJing 210033)
出处
《大氮肥》
CAS
2016年第6期414-417,共4页
Large Scale Nitrogenous Fertilizer Industry
关键词
离心式空气压缩机
故障
静电腐蚀
centrifugal compressor
malfunction
static corrosion