期刊文献+

基于传递函数的GIS特高频传感器性能对比评价方法 被引量:5

Property Comparison and Evaluation Method for Ultra-High-Frequency Sensors Installed on GIS Based on Transfer Function
下载PDF
导出
摘要 在现有的基于等效脉冲的灵敏度现场校验方法中,难以获取标准化的局部放电等效脉冲,且无法使用一致的脉冲注入方式,从而不能量化评价GIS特高频传感器的性能及其布置方式的合理性。为此,提出基于传递函数的GIS特高频传感器性能对比评价方法。通过测量安装在GIS设备上的相邻两特高频传感器之间的传递函数来评价传感器及其布局方案的合理性。利用此方法,对安装在550 k V GIS设备上的内置式传感器进行了现场校验,发现了传感器失效、布局不合理等问题。该方法对于校验特高频传感器的有效性和布局合理性具有明显的效果,对于保证GIS局部放电检测有效性具有非常重要的意义。 Property and arrangement of Ultra-High- Frequency (UHF) sensors installed on GIS cannot be evaluated quantitatively with existing sensitivity verification method based on equivalent pulse. It is difficult to obtain standard pulse equivalent to some partial-discharges; therefore, no uniform pulse injection method can be used. To solve this problem, a property comparison and evaluation method for UHF sensors installed on GIS based on transfer function is suggested. Performance and arrangement of UHF sensors are evaluated by measuring and comparing transfer functions of every two adjacent UHF sensors installed on GIS. By using this method, some sensors installed on 550kV GISs are evaluated in two substations. A damaged sensor is detected and some poor arrangement is found out. This evaluation method is effective to find out disabled sensors and poor arrangement. This work is of great importance to verify effectiveness of GIS partial discharge detection.
出处 《电网技术》 EI CSCD 北大核心 2017年第2期651-655,共5页 Power System Technology
关键词 GIS 局部放电 特高频 传感器 传递函数 对比 评价 GIS partial discharge ultra-high-frequency sensor transfer function comparison evaluation
  • 相关文献

参考文献15

二级参考文献183

共引文献444

同被引文献50

引证文献5

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部