期刊文献+

一种改进的抗干扰自适应算法及其在变压器有源噪声控制中的应用 被引量:9

The Modified Anti-Interference Adaptive Algorithm and It's Application During Active Control of Transformer Noise
下载PDF
导出
摘要 在电力变压器有源降噪系统实际运行时,声传感器采集的参考信号和误差信号可能存在冲击干扰,当采用传统的滤波最小均方(filtered-x least mean square,Fx LMS)算法对控制器的参数自适应更新时,控制器易受冲击性干扰的影响而出现振荡甚至是发散。为了抑制冲击性干扰对控制器的影响,提出了归一化滤波语音压缩?律变换的最小均方(normalized filtered-x?law mean square,NFx?LMS)算法。该算法采用经语音压缩?律函数变换后的误差信号的均方作为代价函数,并对参考信号做归一化处理以提高算法鲁棒性。算法可以根据不同声场环境的初级噪声特点选取不同的压缩系数以提高算法的实用性。仿真显示,在冲击性干扰的环境下,论文提出的算法表现出很好的鲁棒性和收敛效果。 In actual application of power transformer active noise control system, signals produced by error and reference microphone contain signals relating to both transformer noise and interference. The interference, especially impulsive interference, deteriorates ANC system by deviating weights of ANC controller from its converged values. In the worst case, it may cause adaptation divergence. In order to reduce effect of the interference, normalized filtered-x IX law LMS algorithm is proposed with minimized squared μ-law of speech compression transformation of error signal as signal is normalized to improve its cost function. Reference robustness of the algorithm. Filter coefficients are updated with a gradient weighting function, which can be controlled with compression parameter to adapt characteristics of sound field of substations. Computer simulations are carried out to verify effectiveness of the proposed algorithm.
出处 《电网技术》 EI CSCD 北大核心 2017年第2期656-662,共7页 Power System Technology
基金 国家自然科学基金项目(51377123)
关键词 有源噪声控制 变压器 冲击性干扰 稳定性 语音压缩?律 active noise control (ANC) transformer impulsive interference stability μ-law of speech compression
  • 相关文献

参考文献4

二级参考文献62

共引文献73

同被引文献119

引证文献9

二级引证文献55

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部