期刊文献+

变压器油温度对Teflon-AF/陶瓷复合膜油气分离性能的影响 被引量:2

Influence of transformer oil temperature on the oil-gas separation characteristics of Teflon-AF/ceramic composite membrane module
下载PDF
导出
摘要 考察了变压器油的温度对Teflon-AF/陶瓷复合膜组件油气分离性能的影响.当变压器油温由40℃增加到60℃时,Teflon-AF/陶瓷复合膜不仅能够缩短各故障气体的平衡时间,而且还能显著提高气体的平衡浓度,其中H2的平衡浓度提高约30%,CO提高约40%,烃类提高约10%.实验表明,恰当的油温能够有效改善Teflon-AF/陶瓷复合膜脱气效果.根据这一规律设计制作了具有油温恒定控制功能的脱气装置,使变压器油温恒定在60℃,可以在1.5h内实现6种故障特征气体的油气平衡,而且监测数据更加准确可靠,有望在变压器在线监测产品中推广应用. The effect of oil temperature on the oil-gas separation characteristics of Teflon - AF/ ceramic composite membrane module was studied. When the temperature increased from 40 °C to 60 °C ,the Teflon - AF/ceramic composite membrane could not only shorten the equilibrium time of all the fault gases, but also remarkably enhance the equilibrium concentration of H2 by about 3 0 % , CO by about 40% , and hydrocarbons by about 10% , indicating that the proper oil temperature can improve the degassing efficacy of this membrane. A temperature controllable degassing machine has been designed based on the experimental results and on which, the oil-gas equilibrium time reduced from 5h to 1.5h and the monitoring data obtained was more precise and repeatable. The machine is quite applicable to the dissolved gas-in-oil monitoring system.
出处 《膜科学与技术》 CAS CSCD 北大核心 2017年第1期121-124,共4页 Membrane Science and Technology
关键词 Teflon-AF/陶瓷复合膜 溶解气体 在线监测 油气分离 脱气装置 Teflon-AF/ceramic composite membrane dissolved gases on-line monitoring oil-gas separa-tion degasser
  • 相关文献

参考文献3

二级参考文献26

  • 1尚丽平,曹铁泽,刘先勇,周方洁.变压器油中溶解气体在线色谱监测综述[J].变压器,2004,41(8):36-39. 被引量:29
  • 2李红雷,张光福,刘先勇,谈克雄.变压器在线监测用的新型油气分离膜[J].清华大学学报(自然科学版),2005,45(10):1301-1304. 被引量:15
  • 3左海洋,洪镇南.变压器油中溶解气体含量检测故障诊断仪的设计[J].南华大学学报(自然科学版),2005,19(F09):112-117. 被引量:3
  • 4阴昌华,王晨.变压器油中溶解气体在线监测技术的研究[J].科技情报开发与经济,2007,17(1):171-173. 被引量:6
  • 5Qin Renyan. Oil/gas separation membrane, its use in fas aensor and process for producing the same[P]. US Pat: 20050086998. 2005 - 04 - 28.
  • 6Lin Chiahung, Wu Chienhien, Huang Pingzn. Grey clustering analysis for incipient fault diagnosis in oil - immersed transformers [J ]. Expert Systems with Applications, 2008, in Press.
  • 7Tsukioka H, Sugawara K, Moil E N. New apparatus for detecting He, CO, and CH4 dissolved in transformer oil [J ]. IEEE Transactions on Electrical Insulation, 1983, EI18(4) : 409 - 419.
  • 8Lindgren S. Power transformer asset management on- line DGA- The new ballgame[ C]. EPRI substation equipment diagnostics conference XI, New Orleans, 2003, February 23 - 26.
  • 9Morgan J E. Transformer Fault Detection[P]. US Pat: 4112737,1978 - 09 - 12.
  • 10Jengdung J, Yoshida W, Cohen Y. A novel ceramic - supported polymer membrane for pervaporation of dilute volatile organic compounds[J]. J Membr Sci, 1999, 162: 269 - 284.