350MW供热机组的低温省煤器经济性分析 被引量:8

Research on the low-temperature of the co-generation unit
下载PDF
导出
摘要 对某350 MW供热机组进行低温省煤器改造,在空预器与除尘器之间加装低温省煤器,在冬季供暖时,利用烟气余热加热热网回水;夏季纯凝工况下,利用余热加热凝结水,排挤汽轮机抽汽,并对改造结果进行了经济性分析。 The design for a 350 MW co -generation unit added the low- temperature economizer was carried out. The low-temperature economizer was laid between the air preheater and the dust remover. During the heating period in winter, the waste heat of the flue gas was used to heat the backwater of the heating network. During the condensing condition, the condensate water was heated by the waste heat. The extraction steam was reduced. The economy analyse was conducted by the thermal test,
出处 《电力科技与环保》 2017年第1期59-60,共2页 Electric Power Technology and Environmental Protection
关键词 供热机组 低温省煤器 余热 co - generation unit low - temperature economizer waste heat
  • 相关文献

参考文献6

二级参考文献22

  • 1李琳,冯择磊,付小军,王培红.汽轮机效率指标的算法模型研究[J].机电信息,2004(13):8-11. 被引量:6
  • 2赵旭东,吴少华,项光明,马春元.循环流化床烟气脱硫装置对电除尘器影响研究[J].热能动力工程,2005,20(4):377-380. 被引量:8
  • 3李勇,金国华,曹祖庆.弗留格尔公式的证明及应用[J].汽轮机技术,1995,37(3):158-162. 被引量:26
  • 4叶超,张然.设置烟气换热器利弊的探析[J].上海电力,2006,19(5):466-468. 被引量:7
  • 5林万超.火电厂热系统定量分析[M].西安:西安交通大学出版社,1985..
  • 6康晓妮.宁夏大坝发电有限责任公司2号锅炉烟气深度冷却器热力性能试验报告[R].西安热工研究院有限公司,2011.
  • 7姜兴.N320-16.18/535/535型320 MW中间再热凝汽式汽轮机热力特性计算书[Z].上海达能环保设备有限公司,2002.
  • 8赵琦.宁夏大坝发电有限责任公司2号锅炉降低排烟温度改造工程低温省煤器(烟深度冷却器)系统安装使用说明书[Z].上海电气电站设备有限公司上海汽轮机厂,2011.
  • 9车得福,庄正宁,李军,等.锅炉原理[M].北京:中国电力出版社,2009.141 - 154.
  • 10方兴国,吴志祥.锅炉烟冷器的应用与节能分析[J].电世界:增刊,2013(9):464-473.