摘要
目的研究环孢素眼用乳剂的制备,建立含量测定方法。方法采用高压均质机制备环孢素眼用乳剂,以高效液相色谱法(HPLC)测定环孢素含量,Gemini C_(18)柱为色谱柱;流动相:乙腈∶水∶甲醇∶磷酸(550∶400∶50∶0.5,v/v),柱温:70℃,流速:1 m L·min^(-1),紫外检测波长:210 nm。结果在0.099 5~0.278 6 mg·m L^(-1)范围内,环孢素峰面积和质量浓度呈良好的线性关系,平均回收率为99.1%,RSD为0.84%。结论该处方和制备工艺可行,含量测定方法准确、可靠。
OBJECTIVE To establish the procedures to produce cyclosporine ophthalmic emulsion and a method for the determination. METHODS Cyclosporine ophthalmic emulsion was prepared by a high-pressure homogenization. The separation was performed on Gemini C18 column,the mobile phase was acetonitrile-water-methanol-phosphoric acid( 550 ∶ 400 ∶ 50 ∶ 0. 5,v / v),with the flow rate of 1m L·min^-1,the detection wavelength was at 210 nm and column temperature was 70 ℃. RESULTS The calibration curve of cyclosporine ophthalmic emulsion was linear within the conventration range of 0.099 5-0.278 6 mg·mL^-1.The average recovery rate of cyclosporine ophthalmic emulsion was 99. 1%( RSD = 0. 84%). CONCLUSION The formulation and preparation technology is feasible,and the determination method is accurate and reliable.
作者
陈宇翔
王娟
魏宗有
陈忠
陈韡彬
江宁宇
CHEN Yuxiang WANG Juan WEI Zongyou CHEN Zhong CHEN Weibin JIANG Ningyu(Fujian Institute of Microbiology, Fuzhou, Fujian 350007, Chin)
出处
《今日药学》
CAS
2017年第1期24-25,29,共3页
Pharmacy Today
基金
福建省自然科学基金(2014J01274)
福州市科技计划项目(2016X0014)
福建省化药技术重大研发平台(2014Y2001)
福州市生物制药行业技术创新中心(2016-PT-36)