摘要
通过查找分析和处理HXD3型0490号机车自动过分相后主断路器自动闭合故障,找出和谐型机车微机控制原理的逻辑关系与实际故障点之间的区别,为以后处理和谐型机车故障积累经验。
By fault analysis and treatment of automatic closing of the main circuit breaker after the autopassing phase separations for HX_D3 0490 electric locomotive,the difference between the logic control of the locomotive microcomputer and the actual fault points was found,which helps to accumulate experience of the troubleshooting for the HX locomotive.
作者
王成
WANG Cheng;Handan Locomotive Depot;
出处
《铁道机车与动车》
2017年第2期43-45,共3页
Railway Locomotive and Motor Car
关键词
HXD3型机车
自动过分相
主断路器
TCMS
扳键开关
HXD3 locomotive
auto-passing phase separations
main circuit breaker
TCMS
key-lifting switch