小议电动排烟窗 被引量:2

Brief Discussion on Electric Exhaust Smoke Window
下载PDF
导出
摘要 针对设置在建筑物内用于自然排烟的电动排烟窗设计问题,对比、分析不同规范、规程之间对于"手动排烟窗""电动排烟窗"术语概念、要求的异同和不足,提出"智能排烟窗"定义;以丁类车间为例列表说明各种电动排烟窗的不同作用,并对专业提资和"宜采用自动控制"的认识进行探讨。 For the design of the electric exhaust smoke windows for natural exhaust smoke from buildings, the similarities, differences and insufficiencies of different specifications and codes in the definitions and requirements of "manual exhaust smoke window" and "electric exhaust smoke window" are compared and analyzed, and the term of "intelligent exhaust smoke window" is proposed. Class D workshop is taken as an example to describe the different effects of various electric exhaust smoke windows. The understanding of professional data providing and "automatic control to be adopted" is discussed.
作者 李顺康 杨捷
出处 《建筑电气》 2017年第2期25-30,共6页 Building Electricity
关键词 自然排烟设施:自动排烟窗:智能排烟 手动排烟窗 手摇开窗机 电动排烟窗 火灾自 动报警系统:专业提资 natural exhaust smoke facilities automatic exhaust smoke window intelligent exhaustsmoke window manual exhaust smoke window manual window opener electric exhaust smokewindow automatic fire alarm system professionaldata providing