期刊文献+

蓄能机组推力轴承镜板泵调试与性能测试 被引量:1

Commissioning and Performance Test of Thrust Bearing Runner Pump for Pump-storage Generator Unit
下载PDF
导出
摘要 针对某抽水蓄能电站首台机组调试阶段机组推力轴承镜板泵不能建压的问题,分析了可能产生的原因。在此基础上,测量了开机过程和额定转速情况下镜板泵流量和出口压力,分别采用短时傅里叶变换和傅里叶变换对压力信号进行分析,指出不同工况下镜板泵出口压力脉动的主频主要表现为泵孔通过频率,且镜板泵在中高转速下存在压力和流量不稳定区,应引起足够注意。 In order to solve problem of pressure establishment failure of thrust [)earing turbine pump on first unit commissioning of a certain pumped storage power station, possible reasons were analyzed. Based oil the commissioning, 1)ressure fluctuation and flow rate have been measured under conditions of unit speed stepping up and rated speed condi tion. Short time Fourier transform and Fourier transform have been employed separately on pressure signals under differ ent conditions. The measurements show that the main frequency of pressure fluctuation is pump access passing frequen cy; under medium and high speed, there is an unstable operation zone with low pressure and flow rate, which should be further studied by researchers and more attention should he paid by maintenance and operation staff.
出处 《水电能源科学》 北大核心 2017年第1期164-167,共4页 Water Resources and Power
基金 国家自然科学基金项目(51309258)
关键词 蓄能机组 推力轴承 镜板泵 压力脉动 泵孔通过频率 性能测试 pump-storage generator unit thrust bearing runner pump pressure fluctuationa pump access passing frequency performance test
  • 相关文献

参考文献7

二级参考文献26

共引文献47

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部