依据BMI值减少冠状动脉CTA辐射剂量

Reducing the radiation dose in coronary CT angiography according to body mass index of the patients
下载PDF
导出
摘要 目的探讨如何依据不同体质量指数(BMI)并使用i DOS3技术来减少256层螺旋CT冠状动脉血管成像(CCTA)的辐射剂量。方法对我院2013年10~12月289例怀疑冠心病患者行CCTA检查,按不同BMI值分为三组,其中BMI<25者168例(A组);25<BMI<30者105例(B组);BMI>30者16例(C组)。每组患者分别降低辐射剂量的30%(方案1)、40%(方案2)及50%(方案3)进行扫描。采用回顾性心电门控+i DOS3技术。对不同组图像质量进行比较。结果 A组、B组及C组的图像质量的平均评分分别为(3.80±0.47)分、(3.69±0.51)分和(3.37±0.62)分,三组间比较差异无统计学意义(F=0.61,P=0.858>0.05)。结论在降低不同百分比辐射剂量条件下的冠状动脉血管成像中,不同BMI患者的图像质量虽然均有所降低,但均符合诊断要求。因此,对不同BMI值人群可采取不同的扫描条件,可达到既使图像质量符合诊断要求,又减少患者辐射剂量的目的。 Objective To study how to reduce the radiation dose of coronary computed tomography angiography(CCTA) by iDOS3 technique according to the body mass index(BMI).Methods A total of 289 patients with suspected coronary heart disease who underwent CCTA in our hospital from October to December 2013 were selected.They were divided into three groups according to the different BMI value:group A(BMI 〈25,168 cases),group B(25〈BMI〈 30,105 cases),group C(BMI〉30,16 cases).The radiation doses were reduced by 30%,40% and 50%.Retrospective ECG gating and iDOS3 technology were used.The image quality of the three groups was compared.Results The average score of image quality in group A,group B and group C were(3.80±0.47),(3.69±0.51) and(3.37±0.62) respectively.The difference was statistically significant(F=0.61,P=0.858〉0.05).Conclusion The image quality of different groups is decreased under the condition of reducing the radiation dose,but all images meet the diagnostic requirements.Therefore,different scanning conditions can be adopted for patients with different BMI values,which can achieve the aim of keeping the image quality and reducing the radiation dose.
出处 《海南医学》 CAS 2017年第3期429-431,共3页 Hainan Medical Journal
基金 海南省自然科学基金(编号:813216)
关键词 体质量指数 冠状动脉 CT血管成像 辐射剂量 Body mass index(BMI) Coronary Computed tomography angiography(CTA) Radiation dose
  • 相关文献

参考文献3

二级参考文献31

  • 1张红叶,杨军,周北凡,武阳丰,李莹,陶寿淇.我国十组人群脑卒中危险因素的前瞻性研究[J].中国慢性病预防与控制,1996,4(4):150-152. 被引量:91
  • 2曹家琪 连志浩 等.队列(群组)研究.流行病学,第2版,第1卷[M].北京:人民卫生出版社,1995.190-206.
  • 3Stolzmann P, Goetti R, Baumueller S, et al. Prospective and retrospective ECG-gating for CT coronary angiography per- form similarly accurate at low heart rates[J]. Eur J Radiol, 2011, 79(1): 85-91.
  • 4Leschka S, Stinn B. Schmid F. et al. Dual source CT coro- nary angiography in severely obese patients: trading of tem- poral resolution and linage noise [J]. Invest Radiol, 2009. 44 (11) .. 720-727.
  • 5Gervaise A. Osemint B. Lecocq S, et al. CT image quality Improvement using adaptive Iterative dose reduction with wide-volume acqmsition on 320-detector CT [J]. Eur Radiol. 2012. 22(2): 295-301.
  • 6Desai GS. Uppot RN u EW, et aI. Impact of iterative re- construction on image quality and radiation dose in multidetec- tor CT of large body sizeadults [J]. Eur Radiol, 2012, 22(8): 1631-1640.
  • 7Austen WG, Edwards JE, Frye RL, et al. A reporting sys- tem on patients evaluated for coronary artery disease. Report of the ad hoe committee for grading of coronary artery diease, council on cardiovascular surgery, american heart assoeiation [J]. Circulation, 1975, 51(4 ): 5-40.
  • 8Park EA, Lee W, Kim KW, et al. 2011 Iterative reconstruc- tion of dual-source coronary CT angiography: assessment of image quality and radiation dose [J]. Int J Cardiovase Imaging (Epub ahead of print), 2012,28(7) : 1775-1786.
  • 9Husmann L, Alkadhi H, Boehm T, et al. Influence of cardiac hemodynamic parameters on coronary artery oPaeification with 64-sliee computed tamography [J]. Eur Radiol, 2006, 16(5) : 1111-1116.
  • 10Pflederer T, RudofSky L, Ropers D, et al. Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography [J]. Am J Roentgenol, 2009, 192 (4) : 1045-1050.

共引文献3338

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部