DVK系统碘吸附器及其配套保温型电加热器的匹配研究和改进 被引量:1

Study and Improvement on Matching Between DVK Iodine Absorber and its Matched Thermal Insulation Type Electrical Heater
下载PDF
导出
摘要 文章阐述了核电厂核燃料厂房通风系统(DVK)碘吸附器及其配套保温型电加热器的技术要求和现状以及存在的问题,介绍了两者间性能匹配的研究试验情况和结果,结果表明改进后的碘吸附器及其保温型电加热器可以满足预期的加热降湿要求,为设计改进和改造提供了可行方案。 Describes the technical requirements,current status and problems of iodine absorber and its thermal insulation type electrical heater for Fuel Building Ventilation(DVK) System of nuclear power station,as well as the research and test of performance matching between DVK iodine absorber and its electrical heater.The result shows that the improved absorber and its electrical heater meet the expected effects of heating dehumidification,which provides feasible solution for equipment design improvement and renovation.
出处 《核科学与工程》 CAS CSCD 北大核心 2016年第6期764-770,共7页 Nuclear Science and Engineering
关键词 温度 相对湿度 碘吸附器 保温型电加热器 Temperature Relative humidity Iodine absorber Thermal insulation type electrical heater
  • 相关文献

参考文献2

二级参考文献5

  • 1贾明,等.气流相对湿度对碘吸附器净化因子的影响试验报告[R].中国辐射防护研究院,2005.
  • 2EDF(法国电力公司)技术说明书通风系统的碘捕集器[R],2002.
  • 3EDF.Fire Resistant Dampers and Shutters in Thermal and Nuclear Power Plants[]..2004
  • 4NRC.Standard Review Plan[]..2007
  • 5Code on Nuclear Air and Gas Treatment Section F. ASME AG-1-2003 . 2003