摘要
大气弥散因子是评价核电厂控制室可居留性的重要参数,美国核管理委员会采用ARCON96程序评估该参数。对ARCON96程序的基本原理及主要理论模型进行分析,并以安全壳表面释放情况为例,对程序中的面源释放扩散模型开展敏感性分析。为ARCON96程序的科学使用提供建议,保障计算的合理性。
The relative concentrations are major parameters for control room habitability assessments. ARCON96 computer code is developed for U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation for control room habitability assessments. The fundamental and the main theoretical models are analyzed. As a building surface release modeling, a sensitivity analysis on relative concentrations of a nuclear power plant containment radiological release is carried out. Some suggestions which would make the calculation more scientific are provided.
出处
《核电子学与探测技术》
CAS
北大核心
2016年第9期978-981,991,共5页
Nuclear Electronics & Detection Technology
基金
国家科技重大专项(2013ZX06002001)资助